Keyword: brilliance
Paper Title Other Keywords Page
MOPRO083 Design Study of High Brilliant Optics at the SPring-8 Storage Ring emittance, photon, optics, electron 283
 
  • Y. Shimosaki, T. Aoki, K. Fukami, K.K. Kaneki, K. Kobayashi, M. Masaki, C. Mitsuda, H. Ohkuma, M. Shoji, K. Soutome, S. Takano, M. Takao
    JASRI/SPring-8, Hyogo-ken, Japan
 
  At the SPring-8 storage ring, design study of beam optics concentrating particularly on increasing brilliance, not flux density, is in progress besides continuous efforts of increasing both brilliance and flux density for the user optics. The natural emittances are theoretically reduced from 2.41 nmrad at 8 GeV to 2.27 nmrad (8 GeV), 1.78 nmrad (7 GeV) and 1.33 nmrad (6 GeV) by utilizing an emittance damping effect by the insertion devices. The designed optics has experimentally been examined at 6 GeV, and the electron beam parameters have been confirmed by measurements at the diagnostics beamlines.
* Y. Shimosaki et al., “New Optics with Emittance Reduction at the SPring-8 Storage Ring”, IPAC13, MOPEA027.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-MOPRO083  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPRO107 Multi-turn ERL-based Synchrotron Light Facility: Injector Design emittance, gun, linac, booster 343
 
  • A.N. Matveenko, T. Atkinson, A.V. Bondarenko, Y. Petenev
    HZB, Berlin, Germany
 
  Funding: Work supported by German Bundesministerium für Bildung und Forschung, Land Berlin, and grants of Helmholtz Association VH NG 636 and HRJRG-214
Multi-turn energy recovery linac based light sources are candidates for the future 4th generation synchrotron light sources. Using the superconducting linac technology, the Femto-Science-Factory (FSF) will provide its users with ultra-bright photon beams of angstrom wavelength at 6 GeV final beam energy. The FSF is intended to be a multi-user facility and offers a variety of operation modes. An overview of the machine layout and magnetic optics design of the installation will be given in this paper with the focus on high brightness injector design.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-MOPRO107  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPRI078 Fast Orbit Feedback Application at MAX IV and SOLARIS Storage Rings storage-ring, controls, feedback, status 1748
 
  • P. Leban, E. Janezic
    I-Tech, Solkan, Slovenia
  • M. Sjöström
    MAX-lab, Lund, Sweden
 
  A common Fast Orbit Feedback (FOFB) application is planned for the new storage rings at MAX IV laboratory and SOLARIS. The application will run in the Beam Position Monitor (BPM) electronics (Libera Brilliance+). Global orbit data concentration will be conducted inside the gigabit data exchange (GDX) modules with a Virtex6 field programmable gate array, which will be daisy-chained around the storage ring. The feedback calculation algorithm is based on the Singular Value Decomposition (SVD) – the PI controller will be applied in the modal space for individual eigenmodes. The calculations will be distributed over all GDX modules to reduce overall latency. Each GDX module will calculate setpoints for four correctors, horizontal or vertical. The new setpoints will be sent directly to the magnet power supply controllers over a serial point-to-point link. This article presents details on FOFB implementation and control topology.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-TUPRI078  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPRO057 Effect of the Electron Beam Emittance on the ILSF Radiation of Sources and Beamline Design emittance, photon, undulator, electron 2075
 
  • A. Gholampour, S. Amiri, H. Ghasem, H. Khosroabadi, J. Rahighi
    ILSF, Tehran, Iran
  • H. Ghasem, M. Lamehi Rashti, J. Rahighi
    IPM, Tehran, Iran
 
  At the Iranian Light Source Facility (ILSF), two different storage ring options are being studied. The designs differ in emittance. In the first option the calculated emittance is 3.278 nm-rad whereas for the second option emittance is 0.937 nm-rad. In this paper the electron beam emittance effects on the source radiation properties from bending magnet, wiggler and undulator, X-ray optics and the beamline design are carefully studied. The present calculations demonstrate that in the case of 0.937 nm-rad brilliance of undulator is increased by a factor of about 5. For bending magnet, flux is reduced almost 1 order of magnitude for hard x-ray regime. Because of smaller size of the source for undulator at the case of 0.937 nm-rad, we can achieve to a smaller spot size and higher resolution with easier focusing systems and usual kind of monochromator than the emittance of 3.278 nm-rad and for the bending magnet hard x-ray beamline, size of the mirrors reduced 30% in the 0.937 nm-rad emittance case, so its result is shorter mirror, low cost and perhaps more challengeable heat load.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-WEPRO057  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPRO058 Photoemission Electron Microscopy Branch of Spectromicroscopy Beamline of the Iranian Light Source Facility undulator, electron, photon, focusing 2078
 
  • S. Amiri, H. Ghasem, A. Gholampour, H. Khosroabadi, J. Rahighi
    ILSF, Tehran, Iran
  • H. Ghasem, M. Lamehi Rashti
    IPM, Tehran, Iran
 
  The Spectromicroscopy beamline is one of the day one beamlines of the Iranian Light Source Facility project in the field of soft x-ray spectroscopy. This beamline is designed to cover the 90-2500eV energy range with about 8000 resolving power, and the minimum spot size of about 10×4 micrometer 2 at sample position. Brilliance, flux and photon size and divergence in the whole range of energy has been calculated for a 4.3m linear undulator using SPECTRA code. This undulator has 1015 ph/s(0.1% B.W.) photon flux at 96 eV energy & 400 mA electron current. A circular pinhole with maximum diameter size of 2.52mm has been inserted in a distance of 10m from the source to pass 95% radiated. Primary layout of this branch includes a collimating mirror, a varied included-angle plane grating monochromator, and a KB bendable elliptical cylinder mirror. The ray tracing calculation by using computational software SHADOW has been done to determine and optimize of the important optical parameters. Three plane gratings with different uniform line density (700, 900, 1200 lines/mm) have been used to cover the whole energy range with the resolving power of 0.75-0.8×104 depending on the photon energy.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-WEPRO058  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPME031 Magnetic Design of the First Prototype Pure Permanent Magnet Undulator for the ILSF undulator, radiation, permanent-magnet, electron 2326
 
  • A. Ramezani Moghaddam, J. Rahighi
    ILSF, Tehran, Iran
  • H. Ghasem
    IPM, Tehran, Iran
  • M. Lamehi Rashti
    Nuclear Science & Technology Research Institute, Tehran, Iran
  • A. Ramezani Moghaddam
    NSTRI, Tehran, Iran
 
  Iranian light source facility (ILSF) is a 3GeV, 400 mA, 3rd generation light source under design and construction. This paper describes the details of the preliminary magnetic design of the first prototype PPM undulator for the ILSF. In the preliminary design, the undulator period and some other parameters have been determined to reach desired x-ray spectrum to be used for soft x-ray application. A PPM layout and a model undulator with 16 poles is used to calculate the properties of the designs.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-WEPME031  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME005 Optimization of an IH-cavity based High Energy Heavy-ion Linac at GSI linac, emittance, cavity, ion 3214
 
  • A. Orzhekhovskaya, G. Clemente, L. Groening, S. Mickat, B. Schlitt
    GSI, Darmstadt, Germany
 
  A new high energy heavy-ion injector (HE-Linac) for the FAIR project was proposed as replacement for the existing post-stripper linac at the GSI UNILAC. Six 108 MHz IH-type drift-tube linac cavities within a total length of about 24 m accelerate the ions (up to U28+) from 1.4 MeV/u up to 11.4 MeV/u. Fast pulsed quadrupole triplet lenses are used for transverse focusing in between the IH cavities. The optimization of the HE linac with respect to the emittance growth reduction is investigated.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME005  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME129 Application of Libera Brilliance+ to Special Purpose BPMs in SuperKEKB instrumentation, luminosity, positron, betatron 3544
 
  • S. Kanaeda, H. Fukuma, H. Ishii, K. Mori, M. Tobiyama
    KEK, Ibaraki, Japan
 
  The KEKB accelerator at KEK is being upgraded to SuperKEKB, and will be starting operation in 2015. SuperKEKB will have 444 Beam Position Monitors (BPMs) in the positron ring (LER), and 466 in the electron ring (HER). Two BPMs in each ring will be newly introduced for measuring fast beam orbit oscillations, and another two BPMs in each ring will be introduced for the fast beam orbit interlock at SuperKEKB. The required resolution is below several μm for fast beam orbit oscillation monitoring, and the requirement for the response time is less than 100 μs for the fast beam orbit interlock. We plan to use the Libera Brilliance+ from Instrumentation Technologies as signal processors for these special purpose BPMs. This paper discusses the application of the Libera Brilliance+ to these special purpose BPMs.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME129  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME143 Measuring Energy Spread Using Beam Screen Monitor and Four Strip-Line Electrodes for Hls II Injector* quadrupole, LabView, emittance, EPICS 3587
 
  • K. Tang, J. Liu, P. Lu, Q. Luo, B.G. Sun, H. Xu, J. Xu, Y.L. Yang, Z.R. Zhou, J.Y. Zou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  In order to nondestructively measure the beam energy spread with a beam energy of 0.8GeV in the injector at the upgrade project of Hefei Light Source (HLS II) in real time, a beam energy spread monitor (BESM) using beam position monitor (BPM) with four stripline electrodes has been developed. And a screen monitor (SM) near the BESM is used to measure beam energy spread destructively. This paper introduces in brief the beam position measurement system and beam transverse profile measurement system. The relationship between the transverse size at the BESM and at the SM (Flag3) is discussed in detail in this report. The result shows that energy spread measuring result of BESM and SM is 0.19% and 0.18% respectively. So we can draw a conclusion that the BESM is capable of nondestructively measuring the beam energy spread.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME143  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME144 Stripline Beam Position Monitor for THz Source Based FEL electronics, impedance, linac, controls 3590
 
  • J. Xu, L. Li, J. Liu, P. Lu, Y.J. Pei, B.G. Sun, K. Tang, J.G. Wang, F.F. Wu, H. Xu, Y.L. Yang, Z.R. Zhou, J.Y. Zou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  A 14MeV Linac with both the micro-pulse repetition rate 2856MHz and the macro-pulse width 6us for the THz Source Based FEL was proposed. In order to measure the beam position, a stripline beam position monitor (BPM) was designed, and a commercial BPM electronics Libera Brilliance Single Pass was adopted. As the input carrier frequency of the BPM electrode signal is 2856MHz, but the operating frequency of the Libera Brilliance Single Pass is 500MHz, so a front-end electronics was needed before the electrode signals feed into Libera Brilliance Single Pass. The front-end electronics was designed to make the BPM electrode signals of 2856MHz convert to 500MHz.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME144  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)