Author: Kalagin, I.V.
Paper Title Page
MOPSA28
DC140 Project: New Dedicated Facility for Applied Science at FLNR Accelerator Complex  
 
  • S.V. Mitrofanov, P.Yu. Apel, S.L. Bogomolov, J. Franko, G.G. Gulbekyan, I.V. Kalagin, N.Yu. Kazarinov, N.F. Osipov, V.A. Semin, V.A. Skuratov
    JINR, Dubna, Moscow Region, Russia
 
  The main activities of Flerov Laboratory of Nuclear Reactions, following its name - are related to fundamental science, but, in parallel, plenty of efforts are paid for practical applications. In 2021, the main its directions are: the production of the heterogeneousμ- and nano-structured materials; testing of electronic components (avionics and space electronics) for radiation hardness; ion-implantation nanotechnology and radiation materials science. Basing on FLNR long term experience in these fields and aiming to improve the instrumentation, the Flerov laboratory of nuclear reactions starts the new project - the dedicated facility for applied science on the basis of the new heavy ion cyclotron DC-140. Following the user¿s requirements, DC140 will be the multi-particle, double - energy machine, capable with light and heavy ions up to bismuth (2.1 and 4.8 MeV/u). The "ion cocktail" mode will be one of the significant parameters of the new cyclotron. The last year’s efforts in the field of cyclotron practical applications in FLNR and general overview of the DC 140 project - the new FLNR facility for applied science, will be presented.  
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPSA48 Simulation of the Electrostatic Deflector of DC140 Cyclotron 202
 
  • A.S. Zabanov, V.I. Lisov
    JINR/FLNR, Moscow region, Russia
  • K. Gikal, G.G. Gulbekyan, I.V. Kalagin, N.Yu. Kazarinov, S.V. Mitrofanov, V.A. Semin
    JINR, Dubna, Moscow Region, Russia
 
  The main activities of Flerov Laboratory of Nuclear Reactions, following its name - are related to fundamental science, but in parallel a lot of efforts are paid for practical applications. Currently, work is underway to create an irradiation facility based on the DC140 cyclotron for applied research at FLNR. The beam transport system will have three experimental beam lines for testing of electronic components (avionics and space electronics) for radiation hardness, for ion-implantation nanotechnology and for radiation materials science. The DC140 cyclotron is intended to accelerate heavy ions with mass-to-charge ratio A/Z within interval from 5 to 8.25 up to two fixed energies 2.124 and 4.8 MeV per unit mass. The intensity of the accelerated ions will be about 1 pmcA for light ions (A<86) and about 0.1 pmcA for heavier ions (A>132). The extraction system based on four main elements - electrostatic deflector, focusing magnetic channel, Permanent Magnet Quadrupole lens and steering magnet. The results of numerical simulation of the electrostatic deflector of DC140 cyclotron are presented in this this paper.  
poster icon Poster MOPSA48 [1.255 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-RuPAC2021-MOPSA48  
About • Received ※ 22 August 2021 — Accepted ※ 20 September 2021 — Issued ※ 09 October 2021  
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPSA50 Axial Injection System of DC140 Cyclotron of FLNR JINR 209
 
  • N.Yu. Kazarinov, V. Bekhterev, G.G. Gulbekyan, I.A. Ivanenko, I.V. Kalagin, S.V. Mitrofanov, N.F. Osipov, V.A. Semin
    JINR, Dubna, Moscow Region, Russia
  • V.I. Lisov
    JINR/FLNR, Moscow region, Russia
 
  Flerov Laboratory of Nuclear Reaction of Joint Institute for Nuclear Research continues the works under creating of FLNR JINR Irradiation Facility based on the cyclotron DC140. The facility will have three experimental beam lines for SEE testing of microchips, for production of track membranes and for solving of applied physics problems. The injection into cyclotron will be realized from the external room temperature 18 GHz ECR ion source. The systems of DC140 cyclotron such as axial injection, main magnet, RF- and extraction systems and beam lines are the reconstruction of the DC72 cyclotron ones. The acceleration in DC140 cyclotron is carried out for two values of harmonic number h = 2,3 of heavy ions with mass-to-charge ratio A/Z within two intervals 5 - 5.5 and 7.5 - 8.25 up to two fixed energies 2.124 and 4.8 MeV per unit mass, correspondingly. The intensity of the accelerated ions will be about 1 pmcA for light ions (A<86) and about 0.1 pmcA for heavier ions (A>132). The design of the axial injection system of the DC140 cyclotron is presented in this report.  
DOI • reference for this paper ※ doi:10.18429/JACoW-RuPAC2021-MOPSA50  
About • Received ※ 27 August 2021 — Revised ※ 07 September 2021 — Accepted ※ 10 September 2021 — Issued ※ 23 October 2021
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPSA51 The Extraction System of DC140 Cyclotron 213
 
  • V.I. Lisov, A.A. Protasov, A.S. Zabanov
    JINR/FLNR, Moscow region, Russia
  • K. Gikal, G.G. Gulbekyan, I.A. Ivanenko, G.N. Ivanov, I.V. Kalagin, N.Yu. Kazarinov, S.V. Mitrofanov, N.F. Osipov, V.A. Semin
    JINR, Dubna, Moscow Region, Russia
 
  The main activities of Flerov Laboratory of Nuclear Reactions, following its name - are related to fundamental science, but, in parallel, plenty of efforts are paid for practical applications. For the moment continues the works under creating irradiation facility based on the cyclotron DC140 which will be dedicated machine for applied researches in FLNR. The beam transport system will have three experimental beam lines for testing of electronic components (avionics and space electronics) for radiation hardness, for ion-implantation nanotechnology and for radiation materials science. The DC140 cyclotron is intended for acceleration of heavy ions with mass-to-charge ratio A/Z within interval from 5 to 8.25 up to two fixed energies 2.124 and 4.8 MeV per unit mass. The intensity of the accelerated ions will be about 1 pmcA for light ions (A<86) and about 0.1 pmcA for heavier ions (A>132). The following elements are used to extract the beam from the cyclotron: electrostatic deflector, focusing magnetic channel, Permanent Magnet Quadrupole lens and steering magnet. The design of the beam extraction system of DC140 cyclotron are presented in this report.  
poster icon Poster MOPSA51 [0.886 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-RuPAC2021-MOPSA51  
About • Received ※ 30 August 2021 — Accepted ※ 20 September 2021 — Issued ※ 24 October 2021  
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
FRA03 Simulation and Design of the Permanent Magnet Multipole for DC140 99
 
  • V.P. Kukhtin, A.A. Firsov, M. Kaparkova, E.A. Lamzin, M.S. Larionov, A. Makarov, A. Nezhentzev, I.Yu. Rodin, N. Shatil
    NIIEFA, St. Petersburg, Russia
  • N.S. Edamenko, D.A. Ovsyannikov
    St. Petersburg State University, St. Petersburg, Russia
  • G.G. Gulbekyan, I.A. Ivanenko, I.V. Kalagin, N.Yu. Kazarinov, N.F. Osipov
    JINR, Dubna, Moscow Region, Russia
  • S.E. Sytchevsky
    Saint Petersburg State University, Saint Petersburg, Russia
 
  Permanent magnet (PM) multipoles in some cases are good candidates in accelerator applications for beam transportation and focusing. The PM quadrupole will be utilized in the DC140 cyclotron which is under construction in JINR. A passive magnetic channel and a PM quad will be used for the compensation of horizontal defocusing in the high and low field regions, respectively. The quad is designed as a set of identical PMs rigidly fixed in a non-magnetic housing and capable to generate a a 8.1 T/m gradient field in the 64x25 mm aperture and 29.926 cm effective length. The error of linear approximation should be 1% or less. A special study was accomplished to define the PM specification reasoning from the demand for desired field strength, simple geometry, minimized nomenclature, and commercial availability. The quad design was selected with the use a 2D analytical model and then optimized in iterative 3D FE simulations with realistic PM shape and magnetic characteristics in mind. The resultant concept is the quad formed with 6 coaxial sections each 5cm in width. Every section has 26 identical PM bricks with the dimensions 11mmx11mmx50mm and different orientations. The PM bricks have remanent induction of 1.185 T and magnetic susceptibility of 0.1. Temperature characteristics and expected lifetime were also analysed. From the results obtained, candidate PM materials were proposed and mechanical and magnetic precision were recommended.  
slides icon Slides FRA03 [1.465 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-RuPAC2021-FRA03  
About • Received ※ 09 September 2021 — Accepted ※ 29 September 2021 — Issued ※ 12 October 2021  
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
FRA04 The Experimental Research of Cyclotron DC-280 Beam Parameters 102
 
  • V.A. Semin, K. Gikal, I.V. Kalagin, N.Yu. Kazarinov, V.I. Mironov, S.V. Mitrofanov, Yu.G. Teterev
    JINR, Dubna, Moscow Region, Russia
  • A. Issatov, L.A. Pavlov, A.A. Protasov
    JINR/FLNR, Moscow region, Russia
 
  The DC-280 is the high intensity cyclotron for Super Heavy Elements Factory in FLNR JINR. It was designed for production of accelerated ions beam with intensity up 10 pµA to energy in range 4 - 8 MeV/n. The beam power is up 3,5 kW. The diagnostics elements shall be capable of withstanding this power. Moreover such intensity beam required continuous control for avoid of equipment damage. Special diagnostic equipment were designed, manufactured and commissioning. During the design the calculation of thermal loads was made. Some of them were tested before installation on cyclotron. Diagnostic elements used on DC-280 cyclotron are described in this paper. The special Faraday cup was designed for beam cur-rent measurement. The moving inner probe and multylamellar probe are inside the cyclotron. The Scanning two-dimension ionization profile monitor was produced for space distribution analysis of accelerated high intensity beam. Inner Pickup electrode system with special elec-tronic was created for beam phase moving analysis. Time of flight system based on two pick-up electrodes for energy measured was placed in transport channel. These and over diagnostic system were commissioned and tested. The results present in report.  
slides icon Slides FRA04 [16.527 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-RuPAC2021-FRA04  
About • Received ※ 29 September 2021 — Revised ※ 30 September 2021 — Accepted ※ 13 October 2021 — Issued ※ 22 October 2021
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)