A   B   C   D   E   F   G   H   I   K   L   M   O   P   Q   R   S   T   U   V   W    

energy-calibration

Paper Title Other Keywords Page
TPPP009 Precise Energy Measurements in Experiments on VEPP-4M Collider polarization, electron, photon, resonance 1138
 
  • A. Bogomyagkov, V.E. Blinov, V.P. Cherepanov, V. Kiselev, E. Levichev, S.I. Mishnev, N.Yu. Muchnoi, S.A. Nikitin, I.B. Nikolaev, D.M. Nikolenko, A.G. Shamov, E. Shubin, A.N. Skrinsky, Yu.A. Tikhonov, D.K. Toporkov, G.M. Tumaikin
    BINP SB RAS, Novosibirsk
  The series of experiments on mass measurements of J/Psi, Psi', X and D mesons have been done on VEPP4-M collider. The accuracy of obtained masses values for psi mesons exceeded world value more than 3 times. Experiment on mass measuremnt of tau lepton is in progress. All these experiments require absolute energy calibration of the beams. Resonant depolarization technique has been used for most accurate energy measurement with relative accuracy of 1 ppm (10-6). Compton backscattering effect is used in developing facility for fast energy measurements. Moller scattering of the beam on polarized gas jet target has been used for beam polarization measurements.  
 
RPAT006 Design and Initial Tests of a Gas Scattering Energy Monitor in the PEFP RFQ and DTL scattering, proton, rfq, linac 997
 
  • S.-H. Han, Y.-S. Cho
    KAERI, Daejon
  Funding: This work is supported by the 21C Frontier R&D program in the Ministry of Science and Technology of the Korean government.

We have developed a gas scattering energy monitor to measure the energy spectrum of the proton beam at the end of 3MeV RFQ and 20MeV DTL for the low energy part of the PEFP(Proton Engineering Frontier Project). The energy monitor is comprised of a Xe scattering chamber, two collimators to reduce the beam intensity, and a surface barrier detector for measuring the proton energy. In order to measure the beam current simultaneously, a faraday cup is incorporated into the energy monitor. The calculated flux attenuation through the 0.2 mm diameter collimator is 3·10-4 and the energy loss is 28 keV. We report on design details and multiple gas scattering of proton beams in Xe gas by using a SRIM code.

 
 
RPPE034 Measurements of the Energy Deposition Profile for 238U Ions with Energy 500 and 950 MEV/U in Stainless Steel and Copper Targets ion, target, heavy-ion, vacuum 2318
 
  • E. Mustafin, I. Hofmann, D. Schardt, K. Weyrich
    GSI, Darmstadt
  • A. Fertman, A. Golubev, A. Kantsyrev, V. Luckjashin
    ITEP, Moscow
  • A. Gnutov, A. Kunin, Y. Panova, V. Vatulin
    VNIIEF, Sarov (Nizhnii Gorod)
  • L.N. Latysheva, N. Sobolevskiy
    RAS/INR, Moscow
  Funding: Supported by the grant of the GSI-INTAS #03-54-3588.

Sub-millimeter wall thickness is foreseen for the vacuum tubes in the magnets of the superconducting dipoles of the SIS100 and SIS300 of the FAIR Project. The Bragg peak of the energy deposition by the U ions in these walls may lie dangerously close to the superconducting cables. Thus the precise knowledge of the dE/dx profile is essential for estimating the heat load by the lost ions in the vicinity of the superconducting wires. Here we present the results of the measurement of the U ion beam energy deposition profile in Cu and stainless steel targets and compare the measured data with the Monte-Carlo simulation using the SHIELD code.