Keyword: LEBT
Paper Title Other Keywords Page
MOPAB159 Matching of an RFQ and Multicusp Ion Source with Compact LEBT rfq, cyclotron, ion-source, simulation 546
 
  • L.H. Waites, J.M. Conrad, J. Smolsky, D. Winklehner
    MIT, Cambridge, Massachusetts, USA
 
  Funding: NSF provided funding for RFQ-DIP project, Draper Laboratory provided fellowship for graduate studnets
The IsoDAR project is a neutrino experiment that requires a high current H2+ beam at 60 MeV/amu, which will be produced by a cyclotron. A critical aspect of the design is the injection, which comprises an ion source, a compact low energy beam transport section (LEBT), and a radio-frequency quadrupole (RFQ) buncher embedded in the cyclotron yoke. The LEBT is optimized to match the desired input Twiss parameters of the RFQ. Here we report on the latest results from the ion source commissioning, and on the design and optimization of the LEBT with matching to the RFQ. With this ion source, we have demonstrated a 76% H2+ fraction at a current density of 11 mA/cm2 in DC mode. The design of the LEBT includes a chopper, steering elements, and focusing elements, to achieve the desired matching, which according to our simulations leads to ~95% transmission from the ion source to the exit of the RFQ.
 
poster icon Poster MOPAB159 [0.851 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB159  
About • paper received ※ 15 May 2021       paper accepted ※ 24 June 2021       issue date ※ 13 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB205 Minerva (MYRRHA Phase 1) RFQ Beam Commissioning rfq, emittance, MMI, linac 675
 
  • A. Gatera, J. Belmans, F. Davin, W. De Cock, F. Doucet, L. Parez, F. Pompon, A. Ponton, D. Vandeplassche
    SCK•CEN, Mol, Belgium
  • F. Bouly
    LPSC, Grenoble Cedex, France
  • C. Joly, L. Perrot
    Université Paris-Saclay, CNRS/IN2P3, IJCLab, Orsay, France
  • H. Podlech
    IAP, Frankfurt am Main, Germany
  • J. Tamura
    JAEA/J-PARC, Tokai-mura, Japan
  • C. Zhang
    GSI, Darmstadt, Germany
 
  Funding: Part of this work was supported by the European Commission Framework Programme H2020, MYRTE project nr. 662186
The MYRRHA project aims at coupling a 600 MeV proton accelerator to a subcritical fission core operating at a thermal power of 60 MW. The nominal proton beam for this ADS has an intensity of 4 mA and is delivered in a quasi-CW mode. Phase 1 of the project will realize a 100 MeV, 4 mA superconducting linac with the mission of ensuring the ADS requirements in terms of reliability and fault tolerance. As part of the reliability optimization program the integrated prototyping of the MINERVA injector is ongoing. The front-end of the injector is composed of an ECR proton source, a 2.6 m long LEBT (low energy beam transport line) and a four-rod RFQ accelerating the beam to 1.5 MeV. The present contribution focuses on the current beam tests on the RFQ, including beam matching, RF conditioning, assessment of the cavities’ performances and accelerated beam characterisation.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB205  
About • paper received ※ 19 May 2021       paper accepted ※ 31 May 2021       issue date ※ 24 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB268 Design of a Continuous Wave Heavy Ion RFQ for BISOL rfq, emittance, ISOL, linac 851
 
  • S. Liu, M.Y. Han, Y.R. Lu, Q.Y. Tan, Z. Wang
    PKU, Beijing, People’s Republic of China
 
  The Beijing isotope separation online (BISOL) facility will be used to study the new physics and technologies at the limit of the nuclear stability. The post accelerator for BISOL facility aims to accelerate radioactive beams to 150MeV/u. As an injector for the downstream superconducting linac, a 4-vane RFQ operating at 81.25MHz is needed to accelerate high-charge-state ions such as 132Sn22+ from 3keV/u to 500keV/u in CW mode. We have compared two kinds of beam dynamics of BISOL RFQ with and without a Multi-Harmonic Buncher (MHB) bunching the continuous wave beam up-stream of the RFQ. The results indicate that it is possible to keep transverse emittance growth within tolerable limits while the longitudinal emittance is much smaller than the design without an external buncher. The acceleration of multi-charge beams simultaneously in the RFQ is also discussed in this paper.  
poster icon Poster MOPAB268 [1.829 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB268  
About • paper received ※ 19 May 2021       paper accepted ※ 25 May 2021       issue date ※ 16 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB404 A Low Emittance Compact Proton Injector for a Proton Therapy Facility proton, ion-source, emittance, rfq 1218
 
  • S.X. Peng, J.E. Chen, B.J. Cui, Z.Y. Guo, Y.X. Jiang, K. Li, T.H. Ma, J. Sun, W.B. Wu, A.L. Zhang, J.F. Zhang
    PKU, Beijing, People’s Republic of China
  • Y.H. Pu
    Shanghai APACTRON Particle Equipment Company Limited, Shanghai, People’s Republic of China
 
  To meet the requirements of a Proton Therapy Facility funded by the National Key Research and Development Program of China, a new compact ion source-LEBT integrated proton injector was developed at Peking University (PKU). It consists of a typical PKU permanent magnet compact 2.45 GHz ECR ion source (PMECRIS) and an electrostatic LEBT with an electrostatic lens, a beam chopper, a set of beam steers, an ACCT, a bellow, an e-trap, and a valve. A 1000 L/s molecular pump is adopted to maintain the vacuum for this integrated injector. The length from RF matching plane to RFQ front flange is about 450 mm. Chopper is used to shorten the pulse length from ms to µs with sharp edges. Test results of this PMECR source prove that it has the ability to deliver a proton beam with a current from 10 mA to 90 mA with a duty factor of 3%(100Hz/0.3ms) and its RMS emittance less than 0.1 mm·mrad at 30 keV. The acceptance tests of this integrated injector have been performed with a 30 keV hydrogen beam. A required proton current of 18 mA with ripple wave less than 0.1 mA successfully passed through a 20 mm aperture diaphragm at RFQ entrance flange. Its rms emittance is about 0.06 mm·mrad.  
poster icon Poster MOPAB404 [1.946 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB404  
About • paper received ※ 19 May 2021       paper accepted ※ 17 August 2021       issue date ※ 18 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPAB169 Overall Concept Design of a Heavy-Ion Injector for XiPAF-Upgrading heavy-ion, rfq, DTL, ion-source 1781
 
  • P.F. Ma, C.T. Du, X. Guan, Y. Lei, M.W. Wang, X.W. Wang, Q.Z. Xing, X.D. Yu, S.X. Zheng
    TUB, Beijing, People’s Republic of China
  • W. Chen, W.L. Liu, W. Lv, M.T. Qiu, B.C. Wang, D. Wang, M.C. Wang, Z.M. Wang, Y.H. Yan, M.T. Zhao
    NINT, Xi’an, People’s Republic of China
 
  A heavy-ion injector can be used for SEE study. In this paper, the primary beam dynamics design of a heavy-ion injector for the XiPAF upgrade is presented. The injector consists of an ECR heavy-ion source, a LEBT, an RFQ, and a DTL. The mass charge ratio can be up to 6.5. The RFQ can accelerate heavy ions to 500 keV/u, and the DTL can accelerate the ions to 2 MeV/u, which can meet the requirement of the synchrotron.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-TUPAB169  
About • paper received ※ 16 May 2021       paper accepted ※ 16 June 2021       issue date ※ 11 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)