Paper | Title | Other Keywords | Page |
---|---|---|---|
WEAO06 | Development of Heavy Ion Radiotherapy Facilities in China | heavy-ion, injection, cyclotron, radiation | 167 |
|
|||
Funding: This work was supported by the Youth Innovation Promotion Association of the Chinese Academy of Sciences (No. 2017453), and the Lanzhou Talent Innovation and Entrepreneurship Project (No. 2019-RC-4). Hadron therapy offers superior dose conformity in the treatment of deep-seated tumors compared with conventional X-ray therapy due to its Bragg-peak feature of energy deposition in organs. Heavy ion medical machine (HIMM) was constructed on the basis of the experience gained from the Heavy Ion Research Facility in Lanzhou-Cooler Storage Ring (HIRFL-CSR) project. The facility consists of an electron cyclotron resonance (ECR) ion source, a cyclotron injector, a compact synchrotron ring, and 5 nozzles. The C5+ beam generated by the ECR ion source is pre-accelerated by the cyclotron to 6.2 MeV/u and then injected into the synchrotron using the charge exchange injection method. The injected beam is accelerated from 6.2 MeV/u to an extraction energy ranging from 120 to 400 MeV/u. This paper introduced the characteristics of HIMM and its development in China. |
|||
![]() |
Slides WEAO06 [2.445 MB] | ||
DOI • | reference for this paper ※ doi:10.18429/JACoW-CYCLOTRONS2022-WEAO06 | ||
About • | Received ※ 07 December 2022 — Revised ※ 10 February 2023 — Accepted ※ 13 February 2023 — Issue date ※ 14 May 2023 | ||
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | ||
THBO02 | SAPT- A Synchrotron Based Proton Therapy | proton, extraction, injection, dipole | 278 |
|
|||
SAPT is a synchrotron based proton therapy which built in Shanghai, china. There are 4 treatment rooms and a main ring, a linac injector and the transport lines that between them. The main ring is a 24.6m long and 8 dipoles synchrotron. The synchrotron employees multi-turn injection and 3rd order extraction. The treatment rooms are ocular beam line, fixed beam line, 180 degree gantry beam line and 360 gantry beam line. Now, the first unit (fixed beam line, 180 degree gantry beam line) has finished the 3rd party testing and clinical trial, will open to patient treatment soon. the accelerator and beam lines will be described in this paper. | |||
![]() |
Slides THBO02 [14.309 MB] | ||
DOI • | reference for this paper ※ doi:10.18429/JACoW-CYCLOTRONS2022-THBO02 | ||
About • | Received ※ 06 December 2022 — Revised ※ 11 February 2023 — Accepted ※ 13 February 2023 — Issue date ※ 05 March 2023 | ||
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | ||