Author: Khojoyan, M.
Paper Title Page
MOP039 First Results of Commissioning of the PITZ Transverse Deflecting Structure 110
 
  • H. Huck, P. Boonpornprasert, A. Donat, J.D. Good, M. Groß, I.I. Isaev, L. Jachmann, D.K. Kalantaryan, M. Khojoyan, W. Köhler, G. Kourkafas, M. Krasilnikov, D. Malyutin, D. Melkumyan, A. Oppelt, M. Otevřel, M. Pohl, Y. Renier, T. Rublack, J. Schultze, F. Stephan, G. Trowitzsch, G. Vashchenko, R.W. Wenndorff, Q.T. Zhao
    DESY Zeuthen, Zeuthen, Germany
  • G. Asova
    INRNE, Sofia, Bulgaria
  • M. A. Bakr
    Assiut University, Assiut, Egypt
  • D. Churanov, L.V. Kravchuk, V.V. Paramonov, I.V. Rybakov, A.A. Zavadtsev, D.A. Zavadtsev
    RAS/INR, Moscow, Russia
  • C. Gerth, M. Hoffmann, M. Hüning
    DESY, Hamburg, Germany
  • C. Hernandez-Garcia
    JLab, Newport News, Virginia, USA
  • M.V. Lalayan, A.Yu. Smirnov, N.P. Sobenin
    MEPhI, Moscow, Russia
  • O. Lishilin, G. Pathak
    Uni HH, Hamburg, Germany
 
  For successful operation of X-ray Free Electron Lasers, one crucial parameter is the ultrashort electron bunch length yielding a high peak current and a short saturation length. In order to effectively compress the bunches during the acceleration process, a detailed understanding of the full longitudinal phase space distribution already in the injector is required. Transverse deflecting RF structures (TDS) can shear the bunch transversely, mapping the longitudinal coordinate to a transverse axis on an observation screen downstream. In addition to the bunch length, the slice emittance along the bunch as well as the full longitudinal phase space can be obtained. At the Photo Injector Test Facility at DESY, Zeuthen site (PITZ), an S-band traveling wave TDS is under commissioning since 2015. This cavity is a prototype for the TDS in the injector part of the European XFEL and has been designed and manufactured by the Institute for Nuclear Research (INR, Moscow, Russia). In this paper, first commissioning results of the system at PITZ are presented and discussed.  
poster icon Poster MOP039 [0.893 MB]  
Export • reference for this paper to ※ LaTeX, ※ Text, ※ IS/RefMan, ※ EndNote (xml)  
 
TUP065 Beam Dynamics Simulation for the Upgraded PITZ Photo Injector Applying Various Photocathode Laser Pulses 501
 
  • M. A. Bakr, M. Khojoyan, M. Krasilnikov, F. Stephan, G. Vashchenko
    DESY Zeuthen, Zeuthen, Germany
  • M. A. Bakr
    Assiut University, Assiut, Egypt
 
  The Photo Injector Test facility PITZ at DESY, Zeuthen site, characterizes and optimizes high brightness electron sources for linac-based Free Electron Laser (FELs) with a specific focus on the requirements of FLASH and the European XFEL. X-ray FELs require high brightness electron beam in terms of high peak current, small transverse emittance and energy spread. Such high quality beams are mandatory for efficient SASE generation in a single pass through long undulators with narrow gaps. Photocathode laser pulse shaping is a powerful tool to optimize the photo injector performance. Recently, a new photocathode laser system capable of producing 3D quasi-ellipsoidal pulses has been installed at PITZ. It is foreseen to operate this new system in parallel to the nominal one that generates cylindrical pulses with various temporal profiles. A set of numerical simulations was performed to study and compare the beam dynamics of electron beams produced with 3D ellipsoidal laser profile with the typical cylindrically shaped (flat-top) profile. Different bunch charges from 20 pC up to several nC are considered, in order to find an optimum PITZ machine setup which will yield the lowest transverse emittance. we present and discuss the results of this comparison in the submission.  
Export • reference for this paper to ※ LaTeX, ※ Text, ※ IS/RefMan, ※ EndNote (xml)  
 
TUP034 New Ellipsoidal Photocathode Laser Pulses at the Upgraded PITZ Facility 439
 
  • J.D. Good, P. Boonpornprasert, M. Groß, H. Huck, I.I. Isaev, D.K. Kalantaryan, G. Kourkafas, M. Krasilnikov, D. Melkumyan, A. Oppelt, M. Otevřel, Y. Renier, T. Rublack, F. Stephan, G. Vashchenko
    DESY Zeuthen, Zeuthen, Germany
  • A.V. Andrianov, E. Gacheva, E. Khazanov, S. Mironov, A. Poteomkin, V. Zelenogorsky
    IAP/RAS, Nizhny Novgorod, Russia
  • G. Asova
    INRNE, Sofia, Bulgaria
  • M. A. Bakr
    Assiut University, Assiut, Egypt
  • I. Hartl, S. Schreiber
    DESY, Hamburg, Germany
  • C. Hernandez-Garcia
    JLab, Newport News, Virginia, USA
  • M. Khojoyan
    SOLEIL, Gif-sur-Yvette, France
  • O. Lishilin, G. Pathak
    Uni HH, Hamburg, Germany
  • D. Malyutin
    HZB, Berlin, Germany
  • E. Syresin
    JINR, Dubna, Moscow Region, Russia
  • Q.T. Zhao
    IMP/CAS, Lanzhou, People's Republic of China
 
  High brightness electron sources for free electron lasers like FLASH and the European XFEL are developed, optimized and characterized at the Photo Injector Test facility at DESY in Zeuthen (PITZ). Last year the facility was significantly upgraded with a new prototype photocathode laser capable of producing homogeneous ellipsoidal pulses. Previous simulations have shown that the corresponding pulses produce high brightness electron bunches with minimized emittance. Furthermore, a new normal conducting RF gun cavity was installed with a modified two-window waveguide RF feed layout for stability and reliability tests, as required for the European XFEL. Other relevant additions to the facility include beamline modifications for improved electron beam transport through the PITZ accelerator, refinement of both the cooling and RF systems for improved parameter stability, and preparations for the installation of a plasma cell. This paper describes the facility upgrades and reports on the operational experience with the new components.  
poster icon Poster TUP034 [1.211 MB]  
Export • reference for this paper to ※ LaTeX, ※ Text, ※ IS/RefMan, ※ EndNote (xml)  
 
WEP078 Advances on the LUNEX5 and COXINEL Projects 730
 
  • M.-E. Couprie, C. Benabderrahmane, P. Berteaud, C. Bourassin-Bouchet, F. Bouvet, J.D. Bozek, F. Briquez, L. Cassinari, L. Chapuis, J. Da Silva, J. Daillant, D. Dennetière, Y. Dietrich, M. Diop, J.P. Duval, M.E. El Ajjouri, T.K. El Ajjouri, C. Herbeaux, N. Hubert, M. Khojoyan, M. Labat, N. Leclercq, A. Lestrade, A. Loulergue, J. Lüning, P. Marchand, O. Marcouillé, J.L. Marlats, F. Marteau, C. Miron, P. Morin, A. Nadji, R. Nagaoka, F. Polack, F. Ribeiro, J.P. Ricaud, P. Rommeluère, P. Roy, G. Sharma, K.T. Tavakoli, M. Thomasset, M. Tilmont, M.-A. Tordeux, M. Valléau, J. Vétéran, W. Yang, D. Zerbib
    SOLEIL, Gif-sur-Yvette, France
  • S. Bielawski, M. Le Parquier
    PhLAM/CERCLA, Villeneuve d'Ascq Cedex, France
  • X. Davoine
    CEA/DAM/DIF, Arpajon, France
  • N. Delerue, M. El Khaldi, W. Kaabi, F. Wicek
    LAL, Orsay, France
  • G. Devanz, C. Madec
    CEA/IRFU, Gif-sur-Yvette, France
  • A. Dubois
    CCPMR, Paris, France
  • C. Evain, C. Szwaj
    PhLAM/CERLA, Villeneuve d'Ascq, France
  • D. Garzella
    CEA/DSM/DRECAM/SPAM, Gif-sur-Yvette, France
  • G. Lambert, V. Malka, A. Rousse, C. Thaury
    LOA, Palaiseau, France
  • A. Mosnier
    CEA/DSM/IRFU, France
  • E. Roussel
    Elettra-Sincrotrone Trieste S.C.p.A., Basovizza, Italy
 
  Funding: ERC COXINEL 340015
LUNEX5 (free electron Laser Using a New accelerator for the Exploitation of X-ray radiation of 5th generation) aims at investigating compact and advanced Free Electron Laser (FEL). It comprises one one hand a 400 MeV superconducting linac for studies of advanced FEL schemes, high repetition rate operation (10 kHz), multi-FEL lines, and one the other hand a Laser Wake Field Accelerator (LWFA) for its qualification by a FEL application, an undulator line enabling advanced seeding and pilot user applications in the 40-4 nm spectral range. Following the CDR completion, different R&D programs were launched, as for instance on FEL pulse duration measurement, high repetition rate electro-optical sampling. The COXINEL ERC Advanced Grant aims at demonstrating LWFA based FEL amplification, thanks to a proper electron beam manipulation, with a test experiment under preparation. As a specific hardware is also under development such as a cryo-ready 3 m long undulator of 15 mm period is under development.
 
Export • reference for this paper to ※ LaTeX, ※ Text, ※ IS/RefMan, ※ EndNote (xml)