TUP083 | Performance of the 650 MHz SRF Cavity Tuner for PIP II Project | 652 |
|
||
The PIP-II linac will include fifty seven 650MHz SRF cavities. Each cavity will be equipped with tuner for coarse and fine frequency tuning. Design and operations parameters will be discussed. Results from room temperature tests with prototype tuner installed on a 650MHz ¿G=0.90 elliptical cavity will be presented. | ||
![]() |
Poster TUP083 [1.567 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2019-TUP083 | |
About • | paper received ※ 23 June 2019 paper accepted ※ 02 July 2019 issue date ※ 14 August 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUP084 | Testing of the Piezo-actuators at High Dynamic Rate Operational Conditions | 656 |
|
||
Reliability of the piezo-actuators that deployed into SRF cavity tuner and operated at high dynamic rate operational conditions made significant impact on the overall performance of the SRF linacs. We tested at FNAL piezo-actuators P-P-844K075 that were developed at Physik Instrumente for LCLS II project. Even these actuators were developed for CW linac we tested them at high dynamic rate inside cryogenic/insulated vacuum environment. Results of the tests will be presented. Different modes of the piezo-actuators failure will be discussed. | ||
![]() |
Poster TUP084 [3.168 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2019-TUP084 | |
About • | paper received ※ 23 June 2019 paper accepted ※ 04 July 2019 issue date ※ 14 August 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THP060 | Experience With LCLS-II Cryomodule Testing at Fermilab | 1018 |
|
||
Funding: This manuscript has been authored by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the U.S. Department of Energy, Office of Science, Office of High Energy Physics. The Cryomodule Test Stand (CMTS1) at Fermilab has been engaged with testing 8-cavity 1.3 GHz cryomodules designed and assembled for the LCLS-II project at SLAC National Accelerator Laboratory since 2016. Over these three years twenty cryomodules have been cooled to 2K and power tested in continuous wave mode on a roughly once per month cycle. Test stand layout and testing procedures are presented together with results from the cryomodules tested to date. Lessons learned and future plans will also be shared. |
||
![]() |
Poster THP060 [2.774 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2019-THP060 | |
About • | paper received ※ 22 June 2019 paper accepted ※ 30 June 2019 issue date ※ 14 August 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THP090 | Characterization of SSR1 Cavities for PIP-II Linac | 1120 |
|
||
A cryomodule of 325 MHz Single Spoke Resonator type 1 (SSR1) superconducting RF cavities is being built at Fermilab for the PIP-II project. Twelve SSR1 cavities were manufactured in industry in USA (10 cavities) and India (2 cavities) and delivered to Fermilab. In this paper we present results of characterization of fully integrated jacketed cavities with high power coupler and tuner at the Fermilab Spoke Test Cryostat (STC). | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2019-THP090 | |
About • | paper received ※ 23 June 2019 paper accepted ※ 01 July 2019 issue date ※ 14 August 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THP091 | Upgrade of the Fermilab Spoke Test Cryostat for Testing of PIP-II 650 MHz 5-Cell Elliptical Cavities | 1124 |
|
||
Design of the high beta 650 MHz prototype cryomodule for PIP-II is currently undergoing at Fermilab. The cryomodule includes six 5-cell elliptical SRF cavities with accelerating voltage up to 20 MV and low heat dissipation (Q0 > 3·10zEhNZeHn). Characterization of performance of fully integrated jacketed cavities with high power coupler and tuner is crucial for the project. Such a characterization of jacketed cavity requires a horizontal test cryostat. Existing horizontal testing facilities at Fermilab, Horizontal Test Stand (HTS) and Spoke Test Cryostat (STC), are not large enough to accommodate jacketed 650 MHz 5-cell cavity. An upgrade of the STC is proposed to install extension to the cryostat and modify cryogenic connections and RF infrastructure to provide testing of 650 MHz cavities. In this paper we describe STC upgrade and commissioning of the upgraded facility. We discuss mitigation of issues and problems specific for testing of high Q0 650 MHz cavities, which require low residual magnetic field and low acoustic and mechanical vibrations environment. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2019-THP091 | |
About • | paper received ※ 23 June 2019 paper accepted ※ 30 June 2019 issue date ※ 14 August 2019 | |