Paper |
Title |
Other Keywords |
Page |
TUP03 |
Extraction System Design for the New IBA Cyclotron for PET Radioisotope Production |
target, extraction, cyclotron, ion |
167 |
|
- W.J.G.M. Kleeven, E. Forton, E.K. Kral, B. Nactergal, V. Nuttens, S. Zaremba, J. van de Walle
IBA, Louvain-la-Neuve, Belgium
|
|
|
At IBA, we have designed, constructed, tested and industrialized an innovative isochronous cyclotron for PET isotope production. The design has been optimized for costeffectiveness, compactness, ease of maintenance and high performances, with a particular emphasis on its application and market. Multiple target stations can be placed around the vacuum chamber. An innovative extraction method (patent applications pending) has been designed which allows to obtain the same extracted beam sizes and properties on the target window independent of the target number. This is achieved by proper design and shaping of the magnet poles. This magnetic design is discussed together with beam dynamics simulations and beam extraction tests on the first machine.
|
|
|
Poster TUP03 [1.246 MB]
|
|