Keyword: interlocks
Paper Title Other Keywords Page
TUPSA27 The First Design of Medium Resolution Mass Spectrometer (MRMS) High Voltage Platform in a SPES Project ion, vacuum, high-voltage, controls 94
 
  • S.L. Andrianov
    ITEP, Moscow, Russia
  • M.F. Moisio, C. R. Roncolato
    INFN/LNL, Legnaro (PD), Italy
 
  A new project of 150 kV high voltage platform (HVP) is developed in a Laboratori Nazionali di Lagnaro as part of SPES (Selective Production of Exotic Species) project for the production of the multiply charged RIB (rare ion beams). The HVP will be located after ECR ion source charge breeder. Medium resolution mass spectrometer (MRMS) is installed at the platform to provide high purity beams with mass resolution about 1/1000. The Draft of platform design including all beamline elements is discussed. There is a several way of feeding equipment on HVP proposed, required engineering services parameters (vacuum system, cooling system, power system and etc) were defined. Some safety measures are proposed.