Author: Copy, B.
Paper Title Page
MOPV010 Working under Pandemic Conditions: Contact Tracing Meets Technology 121
 
  • E. Blanco Viñuela, B. Copy, S. Danzeca, Ch. Delamare, R. Losito, A. Masi, E. Matli, T. Previero, R. Sierra
    CERN, Geneva, Switzerland
 
  Covid-19 has dramatically transformed our working practices with a big change to a teleworking model for many people. There are however many essential activities requiring personnel on site. In order to minimise the risks for its personnel CERN decided to take every measure possible, including internal contact tracing by the CERN medical service. This initially involved manual procedures which relied on people’s ability to remember past encounters. To improve this situation and minimise the number of employees who would need to be quarantined, CERN approved the design of a specific device: the Proximeter. The project goal was to design a wearable device, built in a partnership* with industry fulfilling the contact tracing needs of the medical service. The proximeter records other devices in close proximity and reports the encounters to a cloud-based system. The service came into operation early 2021 and 8000 devices were distributed to personnel working on the CERN site. This publication reports on the service offered, emphasising on the overall workflow of the project under exceptional conditions and the implications data privacy imposed on the design of the software application.
* Terabee. https://www.terabee.com
 
poster icon Poster MOPV010 [3.489 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-ICALEPCS2021-MOPV010  
About • Received ※ 11 October 2021       Revised ※ 26 October 2021       Accepted ※ 03 November 2021       Issue date ※ 18 December 2021
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUBL01 Distributed Caching at Cloud Scale with Apache Ignite for the C2MON Framework 307
 
  • T. Marques Oliveira, M. Bräger, B. Copy, S.E. Halastra, D. Martin Anido, A. Papageorgiou Koufidis
    CERN, Geneva, Switzerland
 
  The CERN Control and Monitoring platform (C2MON) is an open-source platform for industrial controls data acquisition, monitoring, control and data publishing. Its high availability, fault tolerance and redundancy make it a perfect fit to handle the complex and critical systems present at CERN. C2MON must cope with the ever-increasing flows of data produced by the CERN technical infrastructure, such as cooling and ventilation or electrical distribution alarms, while maintaining integrity and availability. Distributed caching is a common technique to dramatically increase the availability and fault tolerance of redundant systems. For C2MON we have replaced the existing legacy Terracotta caching framework with Apache Ignite. Ignite is an enterprise grade, distributed caching platform, with advanced cloud-native capabilities. It enables C2MON to handle high volumes of data with full transaction support and makes C2MON ready to run in the cloud. This article first explains the challenges we met when integrating Apache Ignite into the C2MON framework, and then demonstrates how Ignite enhances the capabilities of a monitor and control system in an industrial controls environment.  
slides icon Slides TUBL01 [0.817 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-ICALEPCS2021-TUBL01  
About • Received ※ 07 October 2021       Revised ※ 20 October 2021       Accepted ※ 01 March 2022       Issue date ※ 05 March 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPV005 OPC-UA Data Acquisition for the C2MON Framework 376
 
  • E. Stockinger
    Aalto University, School of Science and Technology, Aalto, Finland
  • M. Bräger, B. Copy, B. Farnham, M. Ludwig, B. Schofield
    CERN, Geneva, Switzerland
 
  The CERN Control and Monitoring Framework(C2MON) is a monitoring platform developed at CERN and since 2016 made available under an LGPL3 open source license. It stands at the heart of the CERN Technical Infrastructure Monitoring (TIM) that supervises the correct functioning of CERN’s technical and safety infrastructure. This diverse technological infrastructure requires a variety of industrial communication protocols. OPC UA [2], an open and platform-independent architecture, can be leveraged as an integration protocol for a large number of existing data sources, and represents a welcome alternative to proprietary protocols. With the increasing relevance of the open communication standard OPC UA in the world of industrial control, adding OPC UA data acquisition capabilities to C2MON provides an opportunity to accommodate modern and industry-standard compatible use cases. This paper describes the design and development process of the C2MON OPC UA data acquisition module, the requirements it fulfills, as well as the opportunities for innovation it yields in the context of industrial controls at CERN.  
poster icon Poster TUPV005 [0.548 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-ICALEPCS2021-TUPV005  
About • Received ※ 07 October 2021       Revised ※ 23 October 2021       Accepted ※ 20 November 2021       Issue date ※ 13 February 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)