Author: Loehl, F.     [Löhl, F.]
Paper Title Page
TUA04 Status of the SwissFEL C-band Linac 322
 
  • F. Löhl, J. Alex, H. Blumer, M. Bopp, H.-H. Braun, A. Citterio, U. Ellenberger, H. Fitze, H. Jöhri, T. Kleeb, L. Paly, J.-Y. Raguin, L. Schulz, R. Zennaro, C. Zumbach
    PSI, Villigen PSI, Switzerland
 
  The linear accelerator of SwissFEL will be based on C- band technology. This paper summarizes the latest results that were achieved with the first prototype components. Fur- thermore, the progress and plans of the series production are discussed.  
slides icon Slides TUA04 [11.482 MB]  
 
THB02 Experimental Results of Diagnostics Response for Longitudinal Phase Space 657
 
  • F. Frei, V.R. Arsov, H. Brands, R. Ischebeck, B. Kalantari, R. Kalt, B. Keil, W. Koprek, F. Löhl, G.L. Orlandi, Á. Saá Hernández, T. Schilcher, V. Schlott
    PSI, Villigen PSI, Switzerland
 
  At SwissFEL, electron bunches will be accelerated, shaped, and longitudinally compressed by different radio frequency (RF) structures (S-, C-, and X-band) in combination with magnetic chicanes. In order to meet the envisaged performance, it is planned to regulate the different RF parameters based on the signals from numerous electron beam diagnostics. Here we will present experimental results of the diagnostics response on RF phase and field amplitude variations that were obtained at the SwissFEL Injector Test Facility.  
slides icon Slides THB02 [6.110 MB]  
 
THP081
Beam Loss Monitors for the SwissFEL  
 
  • C. Ozkan, M. Calvi, R. Ischebeck, D. Llorente Sancho, F. Löhl, G.L. Orlandi, P. Pollet, V. Schlott, T. Schmidt
    PSI, Villigen PSI, Switzerland
 
  There are currently three types of monitors planned for tracking and minimizing beam losses at the SwissFEL. Fiber-based loss monitors will provide information on the longitudinal loss location, help reduce losses at undulators and measure losses due to insertion of wire scanners for transverse beam profile measurements. They shall be integrated to the Machine Protection System due to their fast response capabilities. The dose deposited over time at the undulators shall be measured with RadFETs and readout using the DOSFET L-02 reader. Characterization of all three types of loss monitors have been carried out at the SwissFEL Injector Test Facility. This contribution shall provide in-depth description of the monitors along with their complete readout chain and results from the characterization studies.  
 
THP091 Design and Test of Wire-Scanners for SwissFEL 948
 
  • G.L. Orlandi, M. Baldinger, H. Brands, P. Heimgartner, R. Ischebeck, A. Kammerer, F. Löhl, R. Lüscher, P. Mohanmurthy, C. Ozkan, B. Rippstein, V. Schlott, L. Schulz, C. Seiler, S. Trovati, P. Valitutti, D. Zimoch
    PSI, Villigen PSI, Switzerland
 
  The SwissFEL light-facility will provide coherent X-rays in the wavelength region 7-0.7 nm and 0.7-0.1 nm. In SwissFEL, view-screens and wire-scanners will be used to monitor the transverse profile of a 200/10pC electron beam with a normalized emittance of 0.4/0.2 mm.mrad and a final energy of 5.7 GeV. Compared to view screens, wire-scanners offer a quasi-non-destructive monitoring of the beam transverse profile without suffering from possible micro-bunching of the electron beam. The main aspects of the design, laboratory characterization and beam-test of the SwissFEL wire-scanner prototype will be presented.