Keyword: background
Paper Title Other Keywords Page
MOPP023 Ionisation Chamber Based Beam Loss Monitoring System for the ESS Linac detector, linac, monitoring, neutron 136
 
  • I. Dolenc Kittelmann, F.S. Alves, E.C. Bergman, C.S. Derrez, T.J. Grandsaert, V. Grishin, T.J. Shea
    ESS, Lund, Sweden
  • W. Cichalewski, G.W. Jabłoński, W. Jałmużna, R. Kiełbik
    TUL-DMCS, Łódź, Poland
 
  The European Spallation Source, currently under construction in Lund, Sweden, will be a neutron source based on partly superconducting linac, accelerating protons to 2GeV with a peak current of 62.5mA, ultimately delivering a 5MW beam to a rotating tungsten target. One of the most critical elements for the protection of an accelerator is its Beam Loss Monitoring (BLM) system. The system is designed to protect the machine from beam-induced damage and unnecessary activation of the components. This contribution focuses on one of the BLM systems to be deployed at the ESS linac, namely the Ionisation Chamber based BLM (ICBLM). Several test campaigns have been performed at various facilities. Results of these tests will be presented here together with an overview of the ESS ICBLM system.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-MOPP023  
About • paper received ※ 04 September 2019       paper accepted ※ 07 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPP027 Development of a Precision Pepper-Pot Emittance Meter emittance, heavy-ion, beam-transport, alignment 369
 
  • G. Hahn
    PAL, Pohang, Republic of Korea
  • J.G. Hwang
    HZB, Berlin, Germany
 
  A fast single-shot emittance measurement device, a pepper-pot emittance meter, was developed. In the manufacturing stage, in order to guarantee the quality of the holes in the pepper-pot mask, we fabricated two mask using different methods that are made of phosphor bronze by optical lithography process and SUS by laser cutting. After the comparison of each SEM (Scanning Electron Microscope) measurement data, the phosphor bronze mask fabricated by lithography was found to be suitable. The rotation and translation matrices are applied on all images obtained by the camera to mitigate the relative angular misalignment errors between MCP, mirror and CMOS camera with respect to the mask. By applying the instrument in the NFRI ion source, the four-dimensional phase-space distribution of ion beams is retrieved and compared with the result measured by using a slit-scan method. In this paper, we describe the fabrication process, data analysis method and beam measurement results of the developed emittance meter.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-TUPP027  
About • paper received ※ 09 September 2019       paper accepted ※ 10 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)