Paper |
Title |
Other Keywords |
Page |
FRCAB6 |
The Effect of Helium Processing and Plasma Cleaning for Low Beta HWR Cavity |
cavity, plasma, experiment, SRF |
1228 |
|
- S.C. Huang, Q.W. Chu, Y. He, C.L. Li, A.D. Wu, S.X. Zhang
IMP/CAS, Lanzhou, People’s Republic of China
|
|
|
The commissioning of the 25 MeV high power and high intensity proton Linac demo for CiADS showed that the performance of the SRF cavities was mainly limited by field emission inside the cavities. Therefore, the techniques of helium processing and reactive oxygen plasma cleaning have been developed to mitigate field emission issues. We performed an experiment with a low beta HWR cavity exposed to air directly and processed by helium and reactive oxygen. In this paper, the details of the experiment will be described, the efficiency of helium processing and plasma cleaning will be compared and discussed
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-SRF2019-FRCAB6
|
|
About • |
paper received ※ 23 June 2019 paper accepted ※ 01 July 2019 issue date ※ 14 August 2019 |
|