Author: Pronitchev, O.V.
Paper Title Page
TUPB004 Vertical Cavity Test Facility at Fermilab 534
 
  • O.S. Melnychuk, A. Grassellino, F.L. Lewis, J.P. Ozelis, R.V. Pilipenko, Y.M. Pischalnikov, O.V. Pronitchev, A. Romanenko, D.A. Sergatskov, B. Squires
    Fermilab, Batavia, Illinois, USA
 
  After a recent upgrade, the vertical test facility for SRF cavities at Fermilab features a low level RF system capable of testing 325MHz, 650MHz, 1.3GHz, and 3.9GHz cavities, helium liquefying plant, three test cryostats, and the interlock safety system. The cryostats can accommodate measurements of multiple cavities in a given cryogenic cycle in the range of temperatures from 4.2K to 1.4K. We present a description of the components of the vertical test facility. We also discuss cavity instrumentation that is used for diagnostics of cavity ambient conditions and quench characterization.  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)  
 
THPB091 Mechanical Design of a High Power Coupler for the PIP-II 325 MHz SSR1 RF Cavity 1354
 
  • O.V. Pronitchev, S. Kazakov
    Fermilab, Batavia, Illinois, USA
 
  The Project X Injector Experiment (PXIE) at Fermilab will include one cryomodule with eight 325 MHz single spoke superconductive cavities (SSR1). Each cavity requires approximately 2 kW CW RF power for 1 mA beam current operation. A future upgrade will require up to 8 kW RF power per cavity. Fermilab has designed and procured ten production couplers for the SSR1 type cavities. Status of the 325 MHz main coupler development for PXIE SSR1 cryomodule is reported.  
poster icon Poster THPB091 [1.821 MB]  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)  
 
THPB092 Mechanical Design of a High Power Coupler for the PIP-II 162.5 MHz RF Quadrupole 1357
 
  • O.V. Pronitchev, S. Kazakov
    Fermilab, Batavia, Illinois, USA
 
  PXIE is a prototype front end system for the proposed PIP-II accelerator upgrade at Fermilab. An integral component of the front end is a 162.5 MHz, normal conducting, continuous wave (CW), radiofrequency quadrupole (RFQ) cavity. Two identical couplers will deliver approximately 100 kW total CW RF power to the RFQ. Fermilab has designed and procured main couplers for the CW RFQ accelerating cavity. The mechanical design of the coupler, along with production status, is presented below.  
poster icon Poster THPB092 [0.476 MB]  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)  
 
THPB098 Testing of 325 MHz Couplers at Test Stand in Resonance Mode 1376
 
  • S. Kazakov, B.M. Hanna, O.V. Pronitchev
    Fermilab, Batavia, Illinois, USA
 
  The linear accelerator for the PIP-II program utilizes two types of 325 MHz Single Spoke resonator cavities: SSR-I and SSR-II. Operating power of SSR-II is about 17 kW and requires input couplers which can reliably work at power levels > 20 kW with full reflection at any reflected phase. Currently only one 10 kW RF amp is available for coupler testing. To increase testing power, a special resonance configuration were used. This configuration allows us to raise RF power approximately 3 times. The testing scheme and results are discussed in the paper.  
poster icon Poster THPB098 [1.600 MB]  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)  
 
FRBA03 SRF, Compact Accelerators for Industry & Society 1467
 
  • R.D. Kephart, B.E. Chase, I.V. Gonin, A. Grassellino, S. Kazakov, T.N. Khabiboulline, S. Nagaitsev, R.J. Pasquinelli, S. Posen, O.V. Pronitchev, A. Romanenko, V.P. Yakovlev
    Fermilab, Batavia, Illinois, USA
  • S. Biedron, S.V. Milton, N. Sipahi
    CSU, Fort Collins, Colorado, USA
  • S. Chattopadhyay
    Northern Illinois Univerity, Dekalb, Illinois, USA
  • P. Piot
    Northern Illinois University, DeKalb, Illinois, USA
 
  Accelerators developed for Science now are used broadly for industrial, medical, and security applications. Over 30,000 accelerators touch over $500B/yr in products producing a major impact on our economy, health, and well being. Industrial accelerators must be cost effective, simple, versatile, efficient, and robust. Many industrial applications require high average beam power. Exploiting recent advances in Superconducting Radio Frequency (SRF) cavities and RF power sources as well as innovative solutions for the SRF gun and cathode system, a collaboration of Fermilab-CSU-NIU has developed a design for a compact SRF high-average power electron linac. Capable of 5-50 kW average power and continuous wave operation this accelerator will produce electron beam energies up to 10 MeV and small and light enough to mount on mobile platforms, such accelerators will enable new in-situ environmental remediation methods and new applications involving in-situ crosslinking of materials. More importantly, we believe this accelerator will be the first of a new class of simple, turn-key SRF accelerators that will find broad application in industry, medicine, security, and science.  
slides icon Slides FRBA03 [2.342 MB]  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)