Author: Hocker, A.
Paper Title Page
MOPB028 Preservation of Very High Quality Factors of 1.3 GHz Nine Cell Cavities From Bare Vertical Test to Dressed Horizontal Test 149
 
  • A. Grassellino, S. Aderhold, M. Checchin, A.C. Crawford, C.J. Grimm, A. Hocker, M. Martinello, O.S. Melnychuk, J.P. Ozelis, S. Posen, A.M. Rowe, D.A. Sergatskov, N. Solyak, R.P. Stanek, G. Wu
    Fermilab, Batavia, Illinois, USA
  • D. Gonnella
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
  • J.M. Köszegi
    HZB, Berlin, Germany
  • M. Liepe
    Cornell University, Ithaca, New York, USA
 
  In this contribution we will report quality factor evolution of several different nine cell N doped cavities with very high Q. The evolution of the quality factor will be reported from bare to dressed in vertical test to dressed in horizontal test with unity coupling to dressed in horizontal test and CM-like environment/configuration (with RF ancillaries). Cooling studies and optimal cooling regimes will be discussed for both vertical and horizontal tests and comparisons will be drawn also for different styles titanium vessels. Studies of sensitivities to magnetic field in final horizontal configuration have been performed by applying a field around the dressed cavity and varying the cooling; parameters required for a very good flux expulsion will be presented.  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)  
 
MOPB033 LCLS-II SRF Cavity Processing Protocol Development and Baseline Cavity Performance Demonstration 159
 
  • M. Liepe, P. Bishop, H. Conklin, R.G. Eichhorn, F. Furuta, G.M. Ge, D. Gonnella, T. Gruber, D.L. Hall, G.H. Hoffstaetter, J.J. Kaufman, G. Kulina, J.T. Maniscalco, T.I. O'Connell, P. Quigley, D.M. Sabol, J. Sears, V. Veshcherevich
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
  • M. Checchin, A.C. Crawford, A. Grassellino, C.J. Grimm, A. Hocker, M. Martinello, O.S. Melnychuk, J.P. Ozelis, A. Romanenko, A.M. Rowe, D.A. Sergatskov, W.M. Soyars, R.P. Stanek, G. Wu
    Fermilab, Batavia, Illinois, USA
  • E. Daly, G.K. Davis, M.A. Drury, J.F. Fischer, A.D. Palczewski, C.E. Reece
    JLab, Newport News, Virginia, USA
  • M.C. Ross
    SLAC, Menlo Park, California, USA
 
  Funding: Work supported, in part, by the US DOE and the LCLS-II Project under U.S. DOE Contract No. DE-AC05-06OR23177 and DE-AC02-76SF00515.
The ”Linac Coherent Light Source-II” Project will construct a 4 GeV CW superconducting RF linac in the first kilometer of the existing SLAC linac tunnel. The baseline design calls for 280 1.3 GHz nine-cell cavities with an average intrinsic quality factor Q0 of 2.7·1010 at 2K and 16 MV/m accelerating gradient. The LCLS-II high Q0 cavity treatment protocol utilizes the reduction in BCS surface resistance by nitrogen doping of the RF surface layer, which was discovered originally at FNAL. Cornell University, FNAL, and TJNAF conducted a joint high Q0 R&D program with the goal of (a) exploring the robustness of the N-doping technique and establishing the LCLS-II cavity high Q0 processing protocol suitable for production use, and (b) demonstrating that this process can reliably achieve LCLS-II cavity specification in a production acceptance testing setting. In this paper we describe the LCLS-II cavity protocol and analyze combined cavity performance data from both vertical and horizontal testing at the three partner labs, which clearly shows that LCLS-II specifications were met, and thus demonstrates readiness for LCLS-II cavity production.
 
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)  
 
MOPB087 Integrated High-Power Tests of Dressed N-doped 1.3 GHz SRF Cavities for LCLS-II 342
 
  • N. Solyak, T.T. Arkan, B.E. Chase, A.C. Crawford, E. Cullerton, I.V. Gonin, A. Grassellino, C.J. Grimm, A. Hocker, J.P. Holzbauer, T.N. Khabiboulline, O.S. Melnychuk, J.P. Ozelis, T.J. Peterson, Y.M. Pischalnikov, K.S. Premo, A. Romanenko, A.M. Rowe, W. Schappert, D.A. Sergatskov, R.P. Stanek, G. Wu
    Fermilab, Batavia, Illinois, USA
 
  New auxiliary components have been designed and fabricated for the 1.3 GHz SRF cavities comprising the LCLS-II linac. In particular, the LCLS-II cavity’s helium vessel, high-power input coupler, higher-order mode (HOM) feedthroughs, magnetic shielding, and cavity tuning system were all designed to meet LCLS-II specifications. Integrated tests of the cavity and these components were done at Fermilab’s Horizontal Test Stand (HTS) using several kilowatts of continuous-wave (CW) RF power. The results of the tests are summarized here.  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)  
 
THAA04 Comparison of Cavity Fabrication and Performances Between Fine Grains, Large Grains and Seamless Cavities 1006
 
  • K. Umemori, H. Inoue, T. Kubo, H. Shimizu, Y. Watanabe, M. Yamanaka
    KEK, Ibaraki, Japan
  • A. Hocker
    Fermilab, Batavia, Illinois, USA
  • T. Tajima
    LANL, Los Alamos, New Mexico, USA
 
  In KEK-CFF, L-band SRF cavity fabrication studies have been actively proceeded. Main target of the R&D is investigation of cavity fabrication methods using different Nb materials. In this talk, we report mainly focus on the experiences obtained from single cell cavity fabrications. First, different Nb materials are compared, between fine grain Nb and large grain(LG) Nb from different vendors including low RRR LG Nb, in which, cavities were fabricated by electron beam welding method. Difficulty on LG cavity fabrication come from deformation due to stressed grain boundaries. In addition to nominal electron beam welded cavities, hydro-formed seamless cavities have been fabricated. Relatively large difference of equator and iris ratio cause difficulty on expansion of Nb pipes. Good qualified Nb pipe is essential and control of hydro-forming steps including annealing of materials is also important. In order to evaluate these cavity performances, vertical tests were carried out. Generally, they showed good performances. In this presentation, fabrication processes, technical difficulties, mitigation strategies and vertical test results are presented.  
slides icon Slides THAA04 [2.810 MB]  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)  
 
THPB041 Hydroforming SRF Cavities from Seamless Niobium Tubes 1176
 
  • M. Yamanaka, H. Inoue, H. Shimizu, K. Umemori
    KEK, Ibaraki, Japan
  • A. Hocker
    Fermilab, Batavia, Illinois, USA
  • T. Tajima
    LANL, Los Alamos, New Mexico, USA
 
  The authors are developing the manufacturing method for super conducting radio frequency (SRF) cavities by using a hydroforming instead of an electron beam welding, which is the major manufacturing method. We expect a cost reduction by hiring the hydroforming. To realize this development, getting a high-purity seamless niobium tube with good forming ability and an advancement of hydroforming technique are necessary. We got the seamless niobium tube made by ATI Wah Chang with the cooperation of Fermilab, and succeeded to manufacture the 1-cell cavity by hydroforming. The accelerating gradient attained to 36 MV/m, and we confirmed it was available to use as the SRF cavity.  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)  
 
THPB089 HOM Coupler Performance in CW Regime in Horizontal and Vertical Tests 1349
 
  • N. Solyak, M.H. Awida, A. Grassellino, C.J. Grimm, A. Hocker, J.P. Holzbauer, T.N. Khabiboulline, O.S. Melnychuk, A.M. Rowe, D.A. Sergatskov, N. Solyak
    Fermilab, Batavia, Illinois, USA
  • J.K. Sekutowicz
    DESY, Hamburg, Germany
 
  Power dissipation in HOM coupler antenna can limit cavity gradient in cw operation. XFEL design of HOM coupler, feedthrough and thermal connection to 2K pipe was accepted for LCLS-II cavity based on simulation results. Recently a series of vertical and horizontal tests was done to prove design for cw operation. In vertical test was found no effect of HOM coupler heating on high-Q cavity performance. In horizontal cryostat HOM coupler was tested up-to 23MV/m in continuous wave mode. Result proves that XFEL HOM coupler meets LCLS-II specifications.  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)  
 
FRAA03 High Gradient Performance in Fermilab ILC Cryomodule 1432
 
  • E.R. Harms, C.M. Baffes, K. Carlson, B.E. Chase, D.J. Crawford, E. Cullerton, D.R. Edstrom, A. Hocker, A.L. Klebaner, M.J. Kucera, J.R. Leibfritz, J.N. Makara, D. McDowell, O.A. Nezhevenko, D.J. Nicklaus, Y.M. Pischalnikov, P.S. Prieto, J. Reid, W. Schappert, W.M. Soyars, P. Varghese, A. Warner
    Fermilab, Batavia, Illinois, USA
 
  Funding: Operated by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the United States Department of Energy.
Fermilab has assembled an ILC like cryomodule using U.S. processed high gradient cavities and achieved an average gradient of 31.5 MV/m for the entire cryomodule. Test results and challenges along the way will be discussed.
 
slides icon Slides FRAA03 [5.878 MB]  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)