JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for MOPB033: LCLS-II SRF Cavity Processing Protocol Development and Baseline Cavity Performance Demonstration

TY - CPAPER
AU - Liepe, M.
AU - Bishop, P.
AU - Checchin, M.
AU - Conklin, H.
AU - Crawford, A.C.
AU - Daly, E.
AU - Davis, G.K.
AU - Drury, M.A.
AU - Eichhorn, R.G.
AU - Fischer, J.F.
AU - Furuta, F.
AU - Ge, G.M.
AU - Gonnella, D.
AU - Grassellino, A.
AU - Grimm, C.J.
AU - Gruber, T.
AU - Hall, D.L.
AU - Hocker, A.
AU - Hoffstaetter, G.H.
AU - Kaufman, J.J.
AU - Kulina, G.
AU - Maniscalco, J.T.
AU - Martinello, M.
AU - Melnychuk, O.S.
AU - O'Connell, T.I.
AU - Ozelis, J.P.
AU - Palczewski, A.D.
AU - Quigley, P.
AU - Reece, C.E.
AU - Romanenko, A.
AU - Ross, M.C.
AU - Rowe, A.M.
AU - Sabol, D.M.
AU - Sears, J.
AU - Sergatskov, D.A.
AU - Soyars, W.M.
AU - Stanek, R.P.
AU - Veshcherevich, V.
AU - Wu, G.
TI - LCLS-II SRF Cavity Processing Protocol Development and Baseline Cavity Performance Demonstration
J2 - Proc. of International Conference on RF Superconductivity (SRF2015), Whistler, BC, Canada, Sept. 13-18, 2015
AB - The ”Linac Coherent Light Source-II” Project will construct a 4 GeV CW superconducting RF linac in the first kilometer of the existing SLAC linac tunnel. The baseline design calls for 280 1.3 GHz nine-cell cavities with an average intrinsic quality factor Q0 of 2.7·10¹⁰ at 2K and 16 MV/m accelerating gradient. The LCLS-II high Q0 cavity treatment protocol utilizes the reduction in BCS surface resistance by nitrogen doping of the RF surface layer, which was discovered originally at FNAL. Cornell University, FNAL, and TJNAF conducted a joint high Q0 R&D program with the goal of (a) exploring the robustness of the N-doping technique and establishing the LCLS-II cavity high Q0 processing protocol suitable for production use, and (b) demonstrating that this process can reliably achieve LCLS-II cavity specification in a production acceptance testing setting. In this paper we describe the LCLS-II cavity protocol and analyze combined cavity performance data from both vertical and horizontal testing at the three partner labs, which clearly shows that LCLS-II specifications were met, and thus demonstrates readiness for LCLS-II cavity production.
PB - JACoW
CY - Geneva, Switzerland
SP - 159
EP - 163
KW - cavity
KW - cryomodule
KW - SRF
KW - linac
KW - vacuum
DA - 2015/12
PY - 2015
SN - 978-3-95450-178-6
DO - 10.18429/JACoW-SRF2015-MOPB033
UR - http://srf2015.vrws.de/papers/mopb033.pdf
ER -