Author: Soldatov, A.P.
Paper Title Page
FRCAMH01 The Carbon Ion Beam Extraction Scheme From the U-70 Synchrotron for Radiobiological Researches 139
 
  • A.V. Maximov, Y.M. Antipov, G.I. Britvich, S.V. Ivanov, V.A. Kalinin, G.V. Khitev, O.P. Lebedev, E.A. Ludmirsky, A.P. Soldatov
    IHEP, Moscow Region, Russia
 
  The carbon ion beam extraction scheme from the U-70 synchrotron of NRC "Kurchatov institute" - IHEP for radiobiological researches is presented. The double-step extraction scheme Piccioni-Wright is used. The beam extraction operates at magnetic field flat bottom of U-70 synchrotron with carbon ion energy 455 MeV/n. A technique to attain transversally uniform dose field and other operational results are also presented.  
slides icon Slides FRCAMH01 [1.978 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-RUPAC2018-FRCAMH01  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPSA33
Radioisotope Centre of Nuclear Medicine  
 
  • A.A. Khasin, R.G. Tertychnyy
    CDNM Ltd, Protvino, Russia
  • V.N. Peleshko, A.P. Soldatov
    IHEP, Moscow Region, Russia
 
  Funding: Work supported by the Ministry of Education and Science of the Russian Federation, the agreement ID 0000000007417-3I0002
The Centre for Development of nuclear medicine (CDNM Ltd) in partnership with the Institute of High Energy Physics of the National Research Centre Kurchatov institute (IHEP) is establishing in Protvino a manufacturing facility on the basis of 70 MeV proton cyclotron. The facility will be focused on production of medical isotopes including Sr-82, Ge-68, Cu-67, and others. Sr-82 and Ge-68 isotopes are of the high demand for production of Sr-82/ Rb 82 and Ge-68/Ga-68 radionuclide generators used in PET (Positron Emission Tomography) diagnostics of cardiac and oncological diseases respectively. Cardiac PET is a superior proven technology, which enables physicians to deliver a diagnosis with less artifactual defects and false-positive results. Wider spread of cardiac PET diagnostics is currently restrained by a shortage of Sr-82 isotope being produced by a limited number of manufacturers worldwide. Establishment of a Russian production site will make it possible to introduce very effective Rb-82- based cardiac PET diagnostics into clinical practices in Russia. CDNM's production facility will run a proton cyclotron Cyclone-70 manufactured by IBA (Ion Beam Applications), Belgium with target devices being developed in partnership with IHEP. CDNM's manufacturing facility will also have a radiochemistry lab for extraction and purification of radionuclide products and quality control laboratory.
 
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)