A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Webber, R.C.

Paper Title Page
TOPC004 Tevatron Beam Position Monitor Upgrade 410
 
  • S.A. Wolbers, B. Banerjee, B. Barker, S. Bledsoe, T. Boes, M. Bowden, G.I. Cancelo, G. Duerling, B. Forster, B. Haynes, B. Hendricks, T. Kasza, R.K. Kutschke, R. Mahlum, M.A. Martens, M. Mengel, M. Olsen, V. Pavlicek, T. Pham, L. Piccoli, J. Steimel, K. Treptow, M. Votava, R.C. Webber, B. West, D. Zhang
    Fermilab, Batavia, Illinois
 
  Funding: Operated by Universities Research Association Inc. under Contract No. DE-AC02-76CH03000 with the United States Department of Energy.

The Tevatron Beam Position Monitor (BPM) readout electronics and software have been upgraded to improve measurement precision, functionality and reliability. The original system, designed and built in the early 1980s, became inadequate for current and future operations of the Tevatron. The upgraded system consists of 960 channels of new electronics to process analog signals from 240 BPMs, new front-end software, new online and controls software, and modified applications to take advantage of the improved measurements and support the new functionality. The new system reads signals from both ends of the existing directional stripline pickups to provide simultaneous proton and antiproton position measurements. Measurements using the new system are presented that demonstrate its improved resolution and overall performance.

 
RPAT015 First Results of a Digital Beam Phase Monitor at the Tevatron 1428
 
  • J.-P. Carneiro, S. U. Hansen, A. Ibrahim, V.D. Shiltsev, J. Steimel, R.C. Webber
    Fermilab, Batavia, Illinois
 
  A digital Beam Phase Monitor has been installed on the Tevatron ring. This device will be mainly use to diagnose the energy oscillations of each of the 36 × 36 protons and antiprotons bunches as well as to study the transient beam loading. The first results obtained from the Beam Phase Monitor will be presented on the paper.  
RPAT017 Using Time Separation of Signals to Obtain Independent Proton and Antiproton Beam Position Measurements Around the Tevatron 1557
 
  • R.C. Webber
    Fermilab, Batavia, Illinois
 
  Funding: Fermilab is operated by Universities Research Association Inc. under Contract No. DE-AC02-76CH03000 with the United States Department of Energy.

Independent position measurement of the counter-circulating proton and antiproton beams in the Tevatron presents a challenge to upgrading the Tevatron Beam Position Monitor (BPM) system. The inherent directionality of the Tevatron BPM pickup design provides 26dB isolation between signals from the two beams. At the present typical 10:1 proton-to-antiproton bunch intensity ratio, this isolation alone is insufficient to support millimeter accuracy antiproton beam position measurements due to interfering proton signals. An accurate and manageable solution to the interfering signal problem is required for antiproton measurements now and, as machine improvements lead to increased antiproton intensity, will facilitate future elimination of antiproton bias on proton beam position measurements. This paper discusses the possibilities and complications of using time separation of the two beam signals at the numerous Tevatron BPM locations and given the dynamic longitudinal conditions of Tevatron operation. Results of measurements results using one such method are presented.

 
RPAT018 Simultaneous Position Measurements of Protons and Anti-Protons in the Tevatron 1613
 
  • R.K. Kutschke, J. Steimel, R.C. Webber, S.A. Wolbers
    Fermilab, Batavia, Illinois
 
  Fermilab has embarked upon a program to upgrade the electronics of the Beam Position Monitor (BPM) system that measures the transverse position of the beams inside the Tevatron collider. The new system improves on the current system in precision, accuracy and reliability. A new feature in the upgraded system is the ability, when both protons and anti-protons are present in the Tevatron, make simultaneous measurements of the closed orbit position of both beam species. The method chosen for achieving the simultaneous measurement is an algorithm that deconvolutes the imperfect directionality of the BPM pickups from the raw measurements. This paper will discuss the algorithm, the calibration of the parameters used by the algorithm and the robustness of the algorithm. It will also present results from the upgraded system which demonstrate that the system meets the requirements set out at the start of the upgrade project.