A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Han, S.-H.

Paper Title Page
TPPE005 50keV, 50mA Pulsed Proton Injector for PEFP 964
 
  • I.-S. Hong, Y.-S. Cho, S.-H. Han
    KAERI, Daejon
 
  Funding: This work is supported by the 21C Frontier R&D program in the Ministry of Science and Technology of the Korean government.

Duoplasmatron type ion source with 50keV proton beam has been constructed and stably operated as the injector for Proton Engineering Frontier Project(PEFP). In DC operation, the beam current of 50mA with 50kV extraction voltage is routinely obtained. However, the pulsed operation mode of the ion source also has been considered to reduce beam induced damage at the entrance of RFQ. A high voltage pulse switch is connected between accelerating electrode and ground electrode for this purpose. The detailed scheme on the focusing of the pulsed proton beam with space charge compensation is in progress. Beam profile and current in front of RFQ will be measured by DCCT and optical measuring tools.

 
RPAT006 Design and Initial Tests of a Gas Scattering Energy Monitor in the PEFP RFQ and DTL 997
 
  • S.-H. Han, Y.-S. Cho
    KAERI, Daejon
 
  Funding: This work is supported by the 21C Frontier R&D program in the Ministry of Science and Technology of the Korean government.

We have developed a gas scattering energy monitor to measure the energy spectrum of the proton beam at the end of 3MeV RFQ and 20MeV DTL for the low energy part of the PEFP(Proton Engineering Frontier Project). The energy monitor is comprised of a Xe scattering chamber, two collimators to reduce the beam intensity, and a surface barrier detector for measuring the proton energy. In order to measure the beam current simultaneously, a faraday cup is incorporated into the energy monitor. The calculated flux attenuation through the 0.2 mm diameter collimator is 3·10-4 and the energy loss is 28 keV. We report on design details and multiple gas scattering of proton beams in Xe gas by using a SRIM code.

 
RPAT007 Status of Beam Diagnostic Systems for the PEFP 1090
 
  • J.H. Park, J.Y. Huang, W.H. Hwang, Y.W. Parc, S.J. Park
    PAL, Pohang, Kyungbuk
  • Y.-S. Cho, B.H. Choi, S.-H. Han
    KAERI, Daejon
 
  Funding: Supported by the PEFP (Proton Engineering Frontier Project).

A proton linear accelerator is currently the construction at the KAERI (Korea Atomic Research Institute) to the PEFP (Proton Engineering Frontier Project) in Korea. We are accomplished the technique development of beam diagnostic system to be currently the construction. We treat beam diagnostics for the high power proton linear accelerator. Prototype beam position & phase monitor (BPPM) electronics was made and tested successfully in one of the beam diagnostic systems. The beam position monitor pickup electrode is a capacitive type (electrostatic type) which has a button form. Button form electrode, in common use around electron synchrotrons and storage rings, are a variant of the electrode with small button form (e.g., sub mm diameter). However, we are designed button form electrode to measure beam position of proton beam. The BCM (Beam Current Monitor) is developed Tuned CT (Current Transformer) for collaborate with Bergoz Instruments. This paper describes the status of beam diagnostic systems for the PEFP.

 
FPAE044 Test Results of the PEFP 3MeV RFQ Upgrade 2842
 
  • Y.-S. Cho, S.-H. Han, J.-H. Jang, H.-S. Kim, Y.-H. Kim, H.-J. Kwon, M.-Y. Park, K.T. Seol
    KAERI, Daejon
 
  Funding: This work is supported by the 21C Frontier R&D program in the Ministry of Science and Technology of the Korean government.

A 3MeV RFQ upgrade for 100MeV proton accelerator has been fabricated at PEFP (Proton Engineering Frontier Project). The tuning of the cavity was carried out before and after the brazing to meet the condition that the quadrupole field profile is within 1% of design value and dipole component is less than 1% of quadrupole one. The ancillary system such as high power RF including klystron power supply and cooling system were already tested up to operating level. Therefore, the main issues of the tests were cavity conditioning up to full power level and low duty beam test. After the completion of the beam test of RFQ itself, the 20MeV DTL which has been tested independently will be carried out. In this paper, the test results of the PEFP 3MeV RFQ upgrade including high power conditioning and low duty beam acceleration are presented.

 
FPAE046 Initial Test of the PEFP 20MeV DTL 2917
 
  • H.-S. Kim, Y.-S. Cho, S.-H. Han, J.-H. Jang, Y.-H. Kim, H.-J. Kwon, M.-Y. Park, K.T. Seol
    KAERI, Daejon
  • Y.-S. Hwang
    SNU, Seoul
 
  Funding: This work is supported by the 21C Frontier R&D program in the Ministry of Science and Technology of the Korean government.

A conventional 20MeV drift tube linac (DTL) for the Proton Engineering Frontier Project (PEFP) has been developed as a low energy section of 100MeV accelerator. The machine consists of four tanks with 152 cells supplied with 900kW RF power from 350MHz klystron through the ridge-loaded waveguide coupler. We assembled the fabricated accelerator components and aligned each part with care. We have also prepared the subsystems for the test of the DTL such as RF power delivery system, high voltage DC power supply, vacuum system, cooling system, measurements and control system and so on. The detailed description of the initial test setup and preliminary test results will be given in this paper.