MOB3CO03 | RHIC Au-Au Operation at 100 GeV in Run16 | 42 |
|
||
In order to achieve higher instantaneous and integrated luminosities, the average Au bunch intensity in RHIC has been increased by 30% compared to the preceding Au run. This increase was accomplished by merging bunches in the RHIC injector AGS. Luminosity leveling for one of the two interaction points (IP) with collisions was realized by continuous control of the vertical beam separation. Parallel to RHIC physics operation, the electron beam commissioning of a novel cooling technique with potential application in eRHIC, Coherent electron Cooling as a proof of principle (CeCPoP), was carried out. In addition, a 56 MHz superconducting RF cavity was commissioned and made operational. In this paper we will focus on the RHIC performance during the 2016 Au-Au run. | ||
![]() |
Slides MOB3CO03 [2.173 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2016-MOB3CO03 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPOB55 | Optimize the Algorithm for the Global Orbit Feedback at Fixed Energies and During Acceleration in RHIC | 612 |
|
||
Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-SC0012704 with the U.S. Department of Energy. To combat triplets vibration, the global orbit feedback system with frequency about 10 Hz was developed and en- gaged in operation at injection and top energy in 2010, dur- ing beam acceleration in 2012 at RHIC. The system has performed well with keeping 6 out of 12 eigenvalues for the orbit response matrix. However, we observed correc- tor current transients with the lattice for polarized proton program in 2015 which resulted in corrector power supply trips. In this report, we will present the observation, an- alyze the cause and also optimize the feedback algorithm to overcome the newly emerged problem with the feedback system. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2016-TUPOB55 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPOB59 | Performance of CEC Pop Gun During Commissioning | 1024 |
|
||
Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy. The Coherent Electron Cooling Proof-of-Principle (CeC PoP) experiment employs a high-gradient CW photo-injector based on the superconducting RF cavity. Such guns operating at high accelerating gradients promise to revolutionize many sciences and applications. They can establish the basis for super-bright monochromatic X-ray and gamma ray sources, high luminosity hadron colliders, nuclear waste transmutation or a new generation of microchip production. In this paper we report on our operation of a superconducting RF electron gun with a high accelerating gradient at the CsK2Sb photo-cathode (i.e. ~ 20 MV/m) generating a record-high bunch charge (above 4 nC). We give short description of the system and then detail our experimental results. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2016-WEPOB59 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPOB60 | Commissioning of CeC PoP Accelerator | 1027 |
|
||
Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy. Coherent electron cooling is new cooling technique to be tested at BNL. Presently we are in the commissioning stage of the accelerator system. In this paper we present status of various systems and achieved beam parameters as well as operational experience. Near term future plans are also discussed. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2016-WEPOB60 | |