Author: Lu, X.
Paper Title Page
THPAB313 Drive Laser System for Shanghai Soft X-Ray Free Electron Laser 4403
 
  • L. Feng, C.L. Li, B. Liu, J.G. Wang
    SARI-CAS, Pudong, Shanghai, People’s Republic of China
  • X. Lu
    ANL, Lemont, Illinois, USA
  • X.T. Wang, W.Y. Zhang
    Shanghai Advanced Research Institute, Pudong, Shanghai, People’s Republic of China
 
  In this paper, we introduce the design and layout of the drive laser of Shanghai Soft X-ray Free Electron Laser (SXFEL). It is known that the temporal and spatial distribution of the drive laser is crucial for high-quality electron beams. The drive laser provides the laser pulse of 266nm wavelength and 8ps pulse duration for the photocathode, as well as 400nm wavelength, 2-20ps tunable pulse duration for the laser heater. For this purpose, there are mainly four parts in such system, including a third-harmonic generation device, pulse stretcher, image transmitted system, and laser optical module for laser heater. Finally, the measured results of the electron beam under this drive laser system are presented and discussed.  
poster icon Poster THPAB313 [0.691 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-THPAB313  
About • paper received ※ 20 May 2021       paper accepted ※ 15 July 2021       issue date ※ 24 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAB163 An X-Band Ultra-High Gradient Photoinjector 2986
 
  • S.V. Kuzikov, S.P. Antipov, P.V. Avrakhov, E. Dosov, C.-J. Jing, E.W. Knight
    Euclid TechLabs, Solon, Ohio, USA
  • G. Ha, C.-J. Jing, W. Liu, P. Piot, J.G. Power, D.S. Scott, J.H. Shao, E.E. Wisniewski
    ANL, Lemont, Illinois, USA
  • C.-J. Jing
    Euclid Beamlabs, Bolingbrook, USA
  • X. Lu
    MIT/PSFC, Cambridge, Massachusetts, USA
  • X. Lu
    SLAC, Menlo Park, California, USA
  • P. Piot
    Fermilab, Batavia, Illinois, USA
  • P. Piot, W.H. Tan
    Northern Illinois University, DeKalb, Illinois, USA
  • E.E. Wisniewski
    IIT, Chicago, Illinois, USA
 
  Funding: This work was supported by DoE SBIR grant # DE-SC0018709.
High brightness beams appealing for XFELs and UEM essentially imply a high current and a low emittance. To obtain such beams we propose to raise the accelerating voltage in the gun mitigating repealing Coulomb forces. An ultra-high gradient is achieved utilizing a short-pulse technology. We have designed a room temperature X-band 1,5 cell gun that is able to inject 4 MeV, 100 pC bunches with as low as 0.15 mcm normalized transverse emittance. The gun is operated with as high gradients as 400 MV/m and fed by 200 MW, 10 ns RF pulses generated with Argonne Wakefield Accelerator (AWA) power extractor. We report results of low RF power tests, laser alignment test results, and successful gun conditioning results carried out at nominal RF power.
 
poster icon Poster WEPAB163 [5.427 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-WEPAB163  
About • paper received ※ 18 May 2021       paper accepted ※ 02 June 2021       issue date ※ 19 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB341 First C-Band High Gradient Cavity Testing Results at LANL 1057
 
  • E.I. Simakov, R.L. Fleming, D. Gorelov, T.A. Jankowski, M.F. Kirshner, J.W. Lewellen, J.D. Pizzolatto, M.E. Schneider, T. Tajima
    LANL, Los Alamos, New Mexico, USA
  • X. Lu, E.A. Nanni, S.G. Tantawi
    SLAC, Menlo Park, California, USA
  • M.E. Middendorf
    ANL, Lemont, Illinois, USA
 
  Funding: Los Alamos National Laboratory LDRD Program.
This poster will report the results of high gradient testing of the two proton β=0.5 C-band accelerating cavities. The cavities for proton acceleration were fabricated at SLAC and tested at high gradient C-band accelerator test stand at LANL. One cavity was made of copper, and the second was made of a copper-silver alloy. LANL test stand was constructed around a 50 MW, 5.712 GHz Canon klystron and is capable to provide power for conditioning single cell accelerating cavities for operation at surface electric fields up to 300 MV/m. These β=0.5 C-band cavities were the first two cavities tested on LANL C-band test stand. The presentation will report achieved gradients, breakdown probabilities, and other characteristics measured during the high power operation.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB341  
About • paper received ※ 19 May 2021       paper accepted ※ 25 May 2021       issue date ※ 30 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)