Author: Hwang, J.-G.
Paper Title Page
MOPAB126 BESSY III & MLS II - Status of the Development of the New Photon Science Facility in Berlin 451
 
  • P. Goslawski, M. Abo-Bakr, F. Andreas, M. Arlandoo, J. Bengtsson, V. Dürr, K. Holldack, J.-G. Hwang, A. Jankowiak, B.C. Kuske, J. Li, A.N. Matveenko, T. Mertens, A. Meseck, E.C.M. Rial, M. Ries, M.K. Sauerborn, A. Schälicke, M. Scheer, P. Schnizer, L. Shi, J. Viefhaus
    HZB, Berlin, Germany
  • J. Lüning
    UPMC, Paris, France
 
  HZB operates and develops two synchrotron radiation sources at Berlin Adlershof. The larger one, BESSY II with an energy of 1.7 GeV and 240 m circumference is optimized for soft-X rays and in operation since 1999. The smaller one is the MLS (Metrology Light Source), owned by the Physikalische Technische Bundesanstalt (PTB) - Germany’s National Metrology Institute. It is designed to fulfill the special metrology needs of the PTB with an energy of 0.6 GeV and 48 m circumference, covering the spectral range from THz and IR to EUV/VUV. In 2020 a discussion process has been started to define the requirements for successors of BESSY II and MLS and to study the possibilities integrate them into a new photon science facility in Berlin Adlershof. Here, we give a status report and present a first envisaged parameter space to both machines (see also MOPAB262, MOPAB220, MOPAB048, MOPAB242).  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB126  
About • paper received ※ 18 May 2021       paper accepted ※ 24 June 2021       issue date ※ 18 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB296 Statistical Analysis of 2D Single-Shot PPRE Bunch Measurements 939
 
  • M. Koopmans, J.-G. Hwang, A. Jankowiak, M. Ries, A. Schälicke, G. Schiwietz
    HZB, Berlin, Germany
 
  The pulse picking by resonant excitation (PPRE) method* is used to realize pseudo single-bunch radiation from a complex filling pattern at the BESSY II storage ring. The PPRE bunch is excited in the horizontal plane by a quasi-resonant incoherent perturbation to increase the emittance of this bunch**. Therefore, the synchrotron light of the PPRE bunch can be separated by collimation from the radiation of the main bunch train at dedicated beamlines for timing users. The properties of the PPRE bunch depend on the storage ring settings and on the excitation parameters. It is not trivial to distinguish between the wanted intrinsic bunch broadening and an additional position fluctuation of the PPRE bunch. Using the potential of the new diagnostics beamline with the possibility to observe an additional spatial dimension with a fast streak camera, we introduce a new method to study the properties of the PPRE bunch***. Applying a statistical analysis to a series of single-turn images enables distinguishing between horizontal orbit motion and the broadening of the bunch due to the excitation. Measurements are presented and the results are compared with data from the BPM system.
* K. Holldack et al., Nature Commun. 5 (2014) 4010.
** J.-G. Hwang et al., Nucl. Instrum. Methods A940 (2019) 387.
*** G. Schiwietz et al., Nucl. Instrum. Methods A990 (2021) 164992.
 
poster icon Poster MOPAB296 [2.074 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB296  
About • paper received ※ 19 May 2021       paper accepted ※ 02 June 2021       issue date ※ 23 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)