Author: Munilla, J.
Paper Title Page
TUPIK030 Characterization of the AMIT Internal Ion Source With a Devoted DC Extraction Test Bench 1740
 
  • D. Obradors-Campos, M.B. Ahedo, J.M. Barcala, J. Calero, P. Calvo, M.A. Domínguez, E.F. Estévez, J.M. Figarola, L. García-Tabarés, D. Gavela, P. Gómez, A. Guirao, J.L. Gutiérrez, J.I. Lagares, D. López, L.M. Martínez, J. Munilla, C. Oliver, J.M. Pérez Morales, I. Podadera, E. Rodríguez García, F. Toral, R. Varela, C. Vázquez
    CIEMAT, Madrid, Spain
  • R. Iturbe, B. López
    ANTEC Magnets SLU, Vizcaya, Spain
 
  Funding: Work partially funded under the Resolution of the Spanish Ministery of Economy, Industry and Competitiveness dated May 24 th, 2016 and project FIS2013-40860-R
With the main aim of a compact machine for 18F and 11C radioisotope production, AMIT cyclotron relies on a superconducting 4T magnet with an internal cold cathode PIG ion source for H production. Given the limited access to the ion source in the cyclotron as well the reduced number of beam diagnostics, an experimental facility was proposed for the commissioning of such ion source. The versatility of this test bench, which includes a movable puller, gives us the opportunity to validate and characterize the ion source behavior as well as to optimize the H production. In a first stage, the discharge characteristics of the ion source has been studied in the CIEMAT IST facilities.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPIK030  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)