Author: Bezditko, O.
Paper Title Page
TUPIK033 Test and Commissioning Results of NSC KIPT 100 MeV/ 100 kW Electron Linear Accelerator, Subcritical Neutron Source Driver 1751
 
  • A.Y. Zelinsky, O.E. Andreev, V.P. Androsov, S.V. Bazarov, O. Bezditko, O.V. Bykhun, Y.L. Chi, A.N. Gordienko, V.A. Grevtsev, A. Gvozd, D.Y. He, X. He, V.E. Ivashchenko, A.A. Kalamayko, I.I. Karnaukhov, I.M. Karnaukhov, X.C. Kong, V.P. Lyashchenko, H.Z. Ma, M. Moisieienko, S. Pei, X.H. Peng, A.V. Reuzayev, I.M. Subotenko, D.V. Tarasov, V.I. Trotsenko, X. Wang
    NSC/KIPT, Kharkov, Ukraine
  • Y.L. Chi, D.Y. He, X. He, X.C. Kong, H.Z. Ma, S. Pei, X.H. Peng, X. Wang
    IHEP, Beijing, People's Republic of China
  • S. Shu
    Institute of High Energy Physics (IHEP), Chinese Academy of Sciences, Beijing, People's Republic of China
 
  Neutron Source on the base of subcritical assembly has been constructed and is under commissioning in NSC KIPT, Kharkov, Ukraine. The source uses 100 MeV/ 100 kW electron linear accelerator as a driver. The accelerator was designed and manufactured in IHEP, Beijing, China. The accelerator has been assembled at NSC KIPT, all accelerator systems and components were and accelerator is under commissioning. Reports describes the status of the NSC KIPT 100 MeV/ 100 kW electron linear accelerator. The results of the first tests are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPIK033  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPVA069 NSC KIPT Experience in Use of Laser Tracker Leica at 401 in Equipment Alignment of 100 MeV/100 KW Electron Linear Accelerator of Neutron Source Driver 4604
 
  • M. Moisieienko, O. Bezditko, I.M. Karnaukhov, A. Mytsykov, A.Y. Zelinsky
    NSC/KIPT, Kharkov, Ukraine
 
  For successful operation of electron linear accelerator that is driver of NSC KIPT Neutron source it is necessary that all the acceleration sections and all the electromagnetic elements should be installed in design position according to the designed lattice. Accuracies of all electromagnetic elements installation are 150 mkm in transverse positions and 200 mrad for all three rotation directions. The whole process, fiducialization and developing of coordinate net, is controlled by Laser tracker Leica AT 401. Well-planned methods allow to realize uniform irradiation of neutron-generation target.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPVA069  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)