Author: Abbasi, F.
Paper Title Page
MOPIK075 Design, Simulation and Compare of Flat Cathode Electron Guns with Spherical Cathode Electron Guns for Industrial Accelerators 702
 
  • M. Nazari, F. Abbasi
    Shahid Beheshti University, Tehran, Iran
  • S. Ahmadiannamin
    ILSF, Tehran, Iran
  • F. Ghasemi
    NSTRI, Tehran, Iran
  • S. Haghtalab
    IPM, Tehran, Iran
 
  In this article, electron guns with flat and spherical cathodes have been designed and simulated for industrial accelerators. After checking the different features of each cathode geometry, there has been discussed about optimum values of this features. The most important features in selecting the best cathode geometry for industrial accelerators are beam waist radius, beam waist position, current density and price. Finally after comparing the different features of both geometries with each other, suitable geometry was selected.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPIK075  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPAB042 Current Status of IPM Linac Control System 1418
SUSPSIK084   use link to see paper's listing under its alternate paper code  
 
  • S. Haghtalab, F. Abbasi
    Shahid Beheshti University, Tehran, Iran
  • S. Ahmadiannamin
    ILSF, Tehran, Iran
  • F. Ghasemi, M. Lamehi
    IPM, Tehran, Iran
 
  This paper reports the progress of the control system for IPM 10 MeV accelerator. As an electron linac, it consists of beam injection acceleration tube, radio frequency production and transmission, target, diagnostics and control and safety. In support of this source, an EPICS-based integrated control system has been designed and being implemented from scratch to provide access to the critical control points and continues to grow to simplify operation of the system. In addition to a PLC-based machine protection component and IO interface, a CSS-based suite of control GUI monitors systems including Modulator and RF, Vacuum, Magnets, and electron gun. An overview of this system is presented in this article.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPAB042  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPAB044 SIMULATION, MEASUREMENT AND TUNING OF A PROTOTYPE DISK LOADED RF CAVITY 1424
 
  • S. Ahmadiannamin
    ILSF, Tehran, Iran
  • F. Abbasi, F. Ghasemi
    Shahid Beheshti University, Tehran, Iran
  • M. Lamehi, M. Shirshekan
    IPM, Tehran, Iran
 
  Constant impedance accelerator RF cavities are constructed from similar resonator cells that stacked to each other. Best operation condition is achieved when all of cells resonate in one resonance frequency with similar quality factors. So, measurement and tuning of RF cavities is the critical step for final best operation of linear accelerators. In this paper, the electromagnetic computer simulations, RF measurement and final tuning of a nine cell periodic accelerator structure was represented. All of cavities tuned in one resonant frequency and according to theoretical concepts we obtain nine resonant modes from RF measurements by vector network analyzer.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPAB044  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPVA085 Design and Construction of 126 MHz Capacity Loaded Aluminium Cavity Prototype 4653
SUSPSIK092   use link to see paper's listing under its alternate paper code  
 
  • S. Ahmadiannamin, J. Rahighi, Kh.S. Sarhadi
    ILSF, Tehran, Iran
  • F. Abbasi
    Shahid Beheshti University, Tehran, Iran
  • M. Lamehi Rashti
    IPM, Tehran, Iran
 
  Iranian light source Facility (ILSF)isa 3 GeV Ultra low emittance synchrotron with 528 meter circumference that will be constructed in the city of Qazvin, located 150km west of Tehran. Motivated by the development of HOM damped cavity with simpler structure at 100 MHz at MAX Lab and also lower costs, 100 MHz RF system is envisaged for ILSF booster and storage ring. An RF cavity prototype was fabricated for better understandingof characteristics of capacity loaded RF cavities by practical investigation. In this paper, design and development of this prototype is presentedwith the simulation and measurement results.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPVA085  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPVA086 Beam Dynamics Studies of an Accelerating Tube for 6 MeV Electron LINAC 4657
 
  • S. Zarei
    Nuclear Science and Technology Research, InstituteRadiation Application School, Tehran, Iran
  • F. Abbasi
    Shahid Beheshti University, Tehran, Iran
  • S. Ahmadiannamin
    ILSF, Tehran, Iran
  • F. Ghasemi
    NSTRI, Tehran, Iran
  • M. Lamehi
    IPM, Tehran, Iran
 
  Side coupled standing wave accelerating tubes are widely used in a low energy linear accelerator because of relatively high accelerating gradient and low sensitivity to construction tolerances. The effective interaction of particles and electromagnetic fields is important for accelerate electrons to intended energy with the greatest efficiency and beam quality output. In this paper, we present the beam dynamics of a 6 MeV Side coupled standing wave accelerating tube using a space charge tracking algorithm (ASTRA). The designed accelerating tube that feeds by a maximum power of 2.6 MW resonant at frequency of 2998.5 MHz in pi/2 mode. 37.5 percent capture efficiency, 6.82 pi-mm-mrad horizontal emittance, 6.78 pi-mm-mrad vertical emittance, 2.24 mm horizontal and vertical beam size and 1079 keV energy spread of the output beam have been determined from the results of beam dynamics studies in ASTRA  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPVA086  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPVA087 Thermal and Mechanical Analysis of 3 GHz Side Coupled RF Cavity for Medical Linacs 4660
 
  • M. Mohseni Kejani, F. Abbasi
    Shahid Beheshti University, Tehran, Iran
  • S. Ahmadiannamin
    ILSF, Tehran, Iran
  • F. Ghasemi
    NSTRI, Tehran, Iran
  • S. Zarei
    Nuclear Science and Technology Research, InstituteRadiation Application School, Tehran, Iran
 
  Medical linear accelerators have wide applications for cancer treatment in the world. Side coupled RF cavities was used in this accelerators for production of X-ray in range of energies between 4 to 25 MeV. Usually, the RF source is magnetron with lower cost in comparison to klystron in this type of applications. Side coupled cavity is a biperiodic structure with sensitive performance to operational thermal and mechanical conditions. In this paper, thermal and mechanical simulations for a period of the structure are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPVA087  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPVA088 DESIGN AND CONSTRUCTION OF BRAZED SIDE COUPLED CAVITY OF MEDICAL ACCELERATOR 4664
 
  • S. Ahmadiannamin, Kh.S. Sarhadi
    ILSF, Tehran, Iran
  • F. Abbasi, M. Mohseni Kejani
    Shahid Beheshti University, Tehran, Iran
  • M. Bahrami, M. Lamehi
    IPM, Tehran, Iran
  • F. Ghasemi
    NSTRI, Tehran, Iran
  • S. Zarei
    Nuclear Science and Technology Research, InstituteRadiation Application School, Tehran, Iran
 
  Two types of standing wave RF cavities are used routinely in construction of medical linear accelerators. These two types are Side coupled and on-axis coupled standing wave cavities. This selection is based on higher shunt impedance and compactness in comparison to travelling wave RF cavities. In this paper, we present the simulation, construction and measurement results of brazed section of 3 GHz side coupled RF cavity. It is the first successful experience of its kind in Iran. The obtained experiences can be used effectively for construction of side coupled thermionic RF guns and RF cavities of medical or industrial linacs.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPVA088  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)