A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Wu, C. Y.

Paper Title Page
TUPC038 Filling Pattern Measurement for the Taiwan Light Source 1137
 
  • C. Y. Wu, J. Chen, K. T. Hsu, K. H. Hu, C. H. Kuo
    NSRRC, Hsinchu
 
  Filling pattern will affect various operation performance of a synchrotron light source. Measurement of the filling pattern correctly is important. The dedicated filling pattern measurement system has been implemented in 2004 for multi-bunch operation in top-up operation mode. Measurement the purity of an isolated bunch by using time correlated single photon counting method is also addressed. Results are presented in this report.  
TUPD007 The Design and Fabrication of the Kicker Power Supply for TPS Project 1446
 
  • C.-S. Fann, K. T. Hsu, S. Y. Hsu, K.-K. Lin, K.-B. Liu, Y.-C. Liu, C. Y. Wu
    NSRRC, Hsinchu
 
  The preliminary test results of the kicker power supply for TPS (Taiwan Photon Source) project will be presented in this report. The achieved capability of this test unit demonstrates that it fulfills the design requirement of providing half-sine pulsed current of 2.5 kA (peak), 5.2 s (base-width), with jitter < 1 ns (peak-to-peak). Both units of using thyratron and IGBT switches are built with the same requirements. The technical considerations of both units for this particular application will be discussed.  
WEOCG02 Post-mortem Diagnostic for the Taiwan Light Source 1932
 
  • K. H. Hu, J. Chen, P. C. Chiu, K. T. Hsu, S. Y. Hsu, C. H. Kuo, D. Lee, C.-J. Wang, C. Y. Wu
    NSRRC, Hsinchu
 
  Analyzing the reasons of various trip events is essential to improve reliability of a synchrotron light source. To identify the causes of trip at Taiwan Light Source (TLS), various diagnostics tool were employed. These diagnostic tools can capture beam trip, interlock signals of superconducting RF system, waveform of the injection kickers, quench and interlock signals of the superconducting insertion device, and instability signals of the stored beam for post-mortem analysis. These diagnostics can be routine monitor signal and record beam trip event. Features of trip diagnostic tools are available now. System configuration experiences will be summarized in this report.  
slides icon Slides  
WEPC082 Technical Considerations of the TPS Linac 2186
 
  • A. P. Lee, H.-P. Chang, J. Chen, C.-S. Fann, K. T. Hsu, S. Y. Hsu, W. K. Lau, K.-K. Lin, K.-B. Liu, Y.-C. Liu, C. Y. Wu
    NSRRC, Hsinchu
 
  The technical considerations of the TPS (Taiwan Photon Source) linac will be presented in this report. A 150 MeV turn-key linac is chosen in this case in order to provide the ease of injection into the booster in which the electron energy will be raised up to 3 GeV. This linac will be similar to that equipping at recently commissioned synchrotron light sources. The major beam parameters are derived from the booster and storage ring injection requirements. The beam diagnostics arrangement for linac commissioning purpose will be briefly described.