Author: Shi, J.
Paper Title Page
MOPWA072 Emittance Exchange Beam Line Design In THU Accelerator Lab 285
 
  • Q. Gao, H.B. Chen, Y.-C. Du, W.-H. Huang, J. Shi
    TUB, Beijing, People's Republic of China
  • W. Gai
    ANL, Argonne, Illinois, USA
 
  Funding: National Natural Science Foundation of China
Emittance exchange (EEX) provides a novel tool to enhance the phase space manipulation techniques. Based on Tsinghua Thomson scattering experimental platform, this study presented a beam line design for exchanging the transverse and longitudinal emittance of an electron bunch. This beam line consists of a 2.856 GHz half-one-half cell deflecting cavity with no axis offset and two doglegs. In this paper, by optimizing the beam envelope parameter for Tsinghua Thomson scattering source, we report the theoretical analysis and a good particle tracking simulation result about emittance exchange and longitudinal shaping.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-MOPWA072  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPJE014 An X-Band Linac with Tunable Beam Energy 1644
 
  • L. Zhang, H.B. Chen, Y.-C. Du, Q.X. Jin, J. Shi, C.-X. Tang, P. Wang, Z. Zhang
    TUB, Beijing, People's Republic of China
 
  The low-energy X-band linac has a wide application in medical imaging. In this paper, an X-band linac is designed to produce beam energy between 0.5MeV and 1.5MeV, and the output beam energy is continuously adjustable within this range. Two sections of linacs are combined and powered by a single microwave source. During the experiment, we can tune the RF phase and amplitude of the second section of the linac, the electron beam can see either acceleration or deceleration, which tunes the output energy. This paper presented the production of the whole linac system, as well as the measurement of the continuously-adjustable beam energy.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-TUPJE014  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPJE020 The Two Beam Acceleration Staging Experiment at Argonne Wakefield Accelerator Facility 2714
 
  • C.-J. Jing, S.P. Antipov, A. Kanareykin, J.Q. Qiu
    Euclid TechLabs, LLC, Solon, Ohio, USA
  • M.E. Conde, D.S. Doran, W. Gai, G. Ha, W. Liu, J.G. Power, J.H. Shao, D. Wang, E.E. Wisniewski
    ANL, Argonne, Illinois, USA
  • J. Shi
    TUB, Beijing, People's Republic of China
 
  Funding: DoE SBIR Program
Staging, defined as the accelerated bunch in a wakefield accelerator continues to gain energy from sequential drive bunches, is one of the most critical technologies, yet be demonstrated, required to achieve high energy. Using the Two Beam Acceleration (TBA) beamline at Argonne Wakefield Accelerator facility, we will perform a staging experiment using two X-band TBA units. The experiment is planned to conduct in steps. We report on the most recent progress.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPJE020  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMN014 A C-band Deflecting Cavity Design for High-precision Bunch Length Measurement 2948
 
  • J. Jiang, H.B. Chen, J. Shi, P. Wang
    TUB, Beijing, People's Republic of China
 
  Funding: NSFC 11375098 and 11327902
A standing wave RF deflecting structure has been designed as a tool for high-precision bunch length measurement. This 3-cell deflecting cavity is designed to operate at a frequency of 5.712GHz. In this paper, the RF design and thermal analysis of the deflecting cavity are introduced. We study the electromagnetic field distribution inside the cavity. The coupler design is also discussed. And the beam dynamics simulation is shown.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPMN014  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMN015 Dark Current Imaging Experiment in an L-band RF Gun 2952
 
  • J.H. Shao, H.B. Chen, J. Shi, D. Wang
    TUB, Beijing, People's Republic of China
  • S.P. Antipov, S.V. Baryshev, C.-J. Jing, J.Q. Qiu
    Euclid TechLabs, LLC, Solon, Ohio, USA
  • M.E. Conde, D.S. Doran, W. Gai, W. Liu, J.G. Power, C. Whiteford, E.E. Wisniewski
    ANL, Argonne, Illinois, USA
  • F.Y. Wang, L. Xiao
    SLAC, Menlo Park, California, USA
 
  The localized high electric field enhancement or low work function is the trigger for strong field emission, which however has yet been well experimentally studied. Using an L-band photocathode gun test stand at Argonne Wakefield Accelerator Facility (AWA), we’ve constructed an imaging beam line to observe field emission current from predefined emitters on cathode. Preliminary experiment results are present. Future plan is discussed.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPMN015  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMN016 Observation of Dark Current Dependence on Stored Energy in an L-Band RF Gun 2956
 
  • J.H. Shao, H.B. Chen, J. Shi, D. Wang
    TUB, Beijing, People's Republic of China
  • S.P. Antipov, S.V. Baryshev, C.-J. Jing, J.Q. Qiu
    Euclid TechLabs, LLC, Solon, Ohio, USA
  • M.E. Conde, D.S. Doran, W. Gai, W. Liu, J.G. Power, C. Whiteford, E.E. Wisniewski
    ANL, Argonne, Illinois, USA
  • F.Y. Wang, L. Xiao
    SLAC, Menlo Park, California, USA
 
  A pin cathode has been installed into an L-band photocathode gun to study the influence of stored energy on field emission. The stored energy was varied by tuning the recess of the cathode in order to have the same E-field on the cathode tip. We have observed 5 times difference of dark current level at the same E-field, while by varying the stored energy by three fold. Dynamics study reveals the difference is not caused by transmission, but by emission process itself. We'll present experiment results and discuss possible mechanisms about the phenomena.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPMN016  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMN018 Measurement of Cell-Cell Coupling Coefficient in Photocathode RF Gun 2963
 
  • P. Wang, H.B. Chen, Q. Gao, J. Shi, L. Zhang
    TUB, Beijing, People's Republic of China
 
  A photocathode RF gun is under cold rest in Tsinghua University. We measured the single cavity frequency and the cell-cell coupling coefficient by the detuning method with high accuracy. We use a simplified model to illustrate the whole process of the measurement. The data obtained in the cold test seem to accord with that from the model very well.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPMN018  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)