Author: Kim, E.-S.
Paper Title Page
MOPHA003 Status of ATF2 IP-BPM Project 777
 
  • O.R. Blanco-García, P. Bambade, F. Bogard, P. Cornebise, S. Wallon
    LAL, Orsay, France
  • D.R. Bett, N. Blaskovic Kraljevic, T. Bromwich
    JAI, Oxford, United Kingdom
  • P. Burrows, G.B. Christian, C. Perry
    Oxford University, Physics Department, Oxford, Oxon, United Kingdom
  • Y. Honda, K. Kubo, S. Kuroda, T. Naito, T. Okugi, T.T. Tauchi, N. Terunuma
    KEK, Ibaraki, Japan
  • S.W. Jang, E.-S. Kim
    KNU, Deagu, Republic of Korea
 
  The efforts during the second half of 2014 towards nano-metric beam position measurement and stabilization at the Interaction Point (IP) section of the Accelerator Test Facility (ATF) at KEK are presented. Recent improvements to the beam position monitor (BPM) data analysis and processing electronics, as well as the installation of a new set of C-Band BPMs, are reviewed.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-MOPHA003  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPTY025 High-current RFQ Design Study on RAON 990
 
  • J. Bahng, E.-S. Kim
    Kyungpook National University, Daegu, Republic of Korea
  • B.H. Choi
    IBS, Daejeon, Republic of Korea
 
  Rare isotope Accelerator Of Newness (RAON) heavy ion accelerator has been designed as a facility for a rare isotepe accelerator of the Rare Isotope Science Project (RISP). RAON provides 400 kW CW heavy ion beams from proton to uranium to support researches in various science fields. The RAON system consists of a few ECR ion source, low energy beam transport systems (LEBTs), CW radio frequency quadrupole (RFQ) accelerators, a medium energy beam transport and superconducting linac. We present the design study of the RFQ accelerator from 30 keV/u to 1.5 MeV/u of deuteron beam with meeting a requirement of over 15 mA beam at the target. We optimized the normal conducting CW RFQ accelerator that has a high transmission and a low longitudinal emittance. In this paper, we will present the design result of RFQ beam dynamics studies and its 2D and 3D EM analysis.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-MOPTY025  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPTY030 Capacitive Linear-Cut Beam Position Monitor Design for Ion Synchrotron at KHIMA Project 998
 
  • J.G. Hwang, C.H. Kim, S.H. Nam, S.Y. Noh
    KIRAMS/KHIMA, Seoul, Republic of Korea
  • G. Hahn, W.T. Hwang, T.K. Yang
    KIRAMS, Seoul, Republic of Korea
  • E.-S. Kim
    Kyungpook National University, Daegu, Republic of Korea
 
  The KHIMA (Korea Heavy Ion Medical Accelerator) project is launched to construct the carbon and proton beam base ion therapy machine. It, which consists of the injector with RFQ and IH-DTL linacs, medium beam transport line, synchrotron, and high energy beam transport line, will be provided the carbon beam up to 430 MeV/u and proton beam up to 230 MeV for cancer therapy. The high precision beam position monitor is required to match and control the beam trajectory for the beam injection and closed orbit in synchrotron. It was also used for measuring the beta-function, tune, and chromaticity. Since the bunch length at heavy ion synchrotron is relatively long, a few meters, a box-like device with long plates of typically 20 cm is used to enhance the signal strength and to get a precise linear dependence with respect to the beam displacement. In this presentation, we show the electromagnetic design of the electrode and surroundings to satisfy the resolution of 100 um, the criteria for mechanical aspect to satisfy the position accuracy of 200 um, the measurement result of position accuracy by using the wire test-bench, and the beam-test results with long (~ 1.6 us) electron beam in PAL.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-MOPTY030  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)