Author: Hsu, K.H.
Paper Title Page
MOPWA042 The Leakage Current Induced by Stray Capacitance in the Pulse Magnet System 762
 
  • C.S. Chen, C.K. Chan, K.H. Hsu, Y.-H. Liu, C.S. Yang
    NSRRC, Hsinchu, Taiwan
 
  A huge amount of current must be provided during the nominal operation of the pulse magnet system in TPS (Taiwan Photon Source). It comes with all kinds of electromagnetic noises, including radiated and conducted EMI (electromagnetic interferences). The primary object of this article is to clarify the paths of induced EMI, especially by means of capacitance induction. Furthermore, some geometrical suggestions which had been tested are listed in this paper as the guidelines of the pulse magnet design. According to the measurement, proper distance and surface area lead to sufficient insulation and reduce the leakage current under the expected value.  
 
MOPWA043 The HV Withstands Test for In Vacuum Booster Kicker 765
 
  • Y.-H. Liu, C.K. Chan, C.S. Chen, H.H. Chen, J.-R. Chen, K.H. Hsu, H.P. Hsueh, Y.T. Huang, C.S. Yang
    NSRRC, Hsinchu, Taiwan
 
  The maximum driving voltage of TPS booster extraction kicker is close to 30 kV, the HV insulation should be carefully noticed. A DC withstand voltage tester MUSASHI 3802 (Model: IP-701G) is used to test the DC breakdown voltage, which the maximum driving voltage is 37 kV. The 10 mm gap between coil and ferrite is designed in order to increase HV break down voltage. The safety breakdown distance between HV coil and grounding plate was tested in air. Different insulation material with different thickness was tested the breakdown voltage. Thicker than 10 mm ceramic plate could effectively avoid the breakdown occurred with 37 kV DC charging. Thus HV withstand voltage will be higher in vacuum chamber and the insulation with HV will not be the problem.  
 
WEPME048 Adjusting and Calibration Method for TPS Laser PSD System 3037
 
  • M.L. Chen, J.-R. Chen, P.S.D. Chuang, H.C. Ho, K.H. Hsu, D.-G. Huang, W.Y. Lai, C.-S. Lin, C.J. Lin, H.C. Lin, H.M. Luo, S.Y. Perng, P.L. Sung, T.C. Tseng, H.S. Wang, M.H. Wu
    NSRRC, Hsinchu, Taiwan
  • J.-R. Chen
    National Tsing Hua University, Hsinchu, Taiwan
 
  Laser PSD positioning system is a part of the TPS girder auto-alignment system and is designed for aligning and positioning the straight-section girders of TPS storage ring. Although the components of Laser PSD system are fabricated, assembling and adjusting precisely in advance, the accuracy of Laser PSD system is still influenced by girder fabricating quality, assembling errors and moving errors by transportation. For system correction, Laser beam positions on four sets of PSDs are formulized as an equation and calibrated with Laser tracker ultimately. According to the PSD calibration formula, the two girders of 18m long straight-section can be aligned and positioned within 20um by comparing with Laser tracker. This paper describes the assembly, installation and calibration process of Laser PSD system.  
 
WEPME049 An Application of Laser Position Sensing Detector for Magnet Centralizing System 3040
 
  • C.-S. Lin, J.-R. Chen, M.L. Chen, P.S.D. Chuang, H.C. Ho, K.H. Hsu, D.-G. Huang, C.K. Kuan, W.Y. Lai, C.J. Lin, H.C. Lin, H.M. Luo, S.Y. Perng, P.L. Sung, T.C. Tseng, H.S. Wang, M.H. Wu
    NSRRC, Hsinchu, Taiwan
  • J.-R. Chen
    National Tsing Hua University, Hsinchu, Taiwan
 
  Taiwan Photon Source (TPS) project has been proposed to create a 3GeV synchrotron light source. The designated ultra-low emittance of this new light source requires high precision positioning of storage ring magnets. The alignment of all magnets is very importance since it directly affects the closed orbit of electron beams. Previously, conventional on-site alignment of the magnets was mainly relying on the theodolite performance. The cumulated errors could be in the order of 0.1mm. In this paper, a new alignment scheme is proposed to enhance the on-site alignment of magnets for TPS project. To achieve the high precision requirements, a device possessing the advantages of expansion mandrel in conjunction with Position Sensing Detector (PSD) is proposed. The development of this alignment device is anticipated to provide a better mechanism to properly align the centers of the both quadrupole and sextupole magnets on girder with less than 30μm positioning errors.  
 
WEPME050 Alignment Design and Status of Taiwan Photon Source 3043
 
  • W.Y. Lai, J.-R. Chen, M.L. Chen, P.S.D. Chuang, H.C. Ho, K.H. Hsu, D.-G. Huang, C.K. Kuan, C.-S. Lin, C.J. Lin, H.C. Lin, H.M. Luo, S.Y. Perng, P.L. Sung, T.C. Tseng, H.S. Wang, M.H. Wu
    NSRRC, Hsinchu, Taiwan
  • J.-R. Chen
    National Tsing Hua University, Hsinchu, Taiwan
 
  Taiwan Photon Source (TPS) is a new 3-GeV ring with characteristics of great brightness and small emittance, at present under construction at National Synchrotron Radiation Research Center (NSRRC) Taiwan. The positioning of the magnets is highly sensitive to alignment errors, and the entire building will be constructed half underground at depth 12 m relative to Taiwan Light Source (TLS) for stability reasons; for these reasons the survey and alignment work is confined and difficult. To position magnets precisely and quickly, a highly accurate auto-tuning girder system combined with a survey network was designed to accomplish the alignment tasks. The survey network includes a preliminary Global Positioning System (GPS) network and a laser tracking network. The position data from the survey network define a basis for the system of motorized girders to auto-tune and to improve the accuracy. The detailed survey and alignment design, installation process is described in this paper.  
 
THPFI078 Design and Experiment on Auto-alignment Control System of Taiwan Photon Source 3475
 
  • M.H. Wu, J.-R. Chen, M.L. Chen, P.S.D. Chuang, H.C. Ho, K.H. Hsu, D.-G. Huang, W.Y. Lai, C.-S. Lin, C.J. Lin, H.C. Lin, H.M. Luo, S.Y. Perng, P.L. Sung, T.C. Tseng, H.S. Wang
    NSRRC, Hsinchu, Taiwan
  • J.-R. Chen
    National Tsing Hua University, Hsinchu, Taiwan
 
  TPS (Taiwan Photon Source) is a new 3-GeV synchrotron ring to be constructed at the NSRRC (National Synchrotron Radiation Research Center), Taiwan. There were hundreds of magnets that must be aligned on the absolute position to keep the electronic beam in the desire path while orbiting. Due to the problems of manpower, set up time, accuracy of adjustment, deformation of the floor, limited workspace and frequent earthquakes in Taiwan, an auto-alignment girder control system was designed to meet this requirement. The design and experiment of the auto-alignment system were tested successfully in the laboratory at NSRRC. The experiment of the auto-alignment control system would be implemented with half of the ring girders in the TPS. The detailed alignment design and status will be discussed in this paper.