Paper | Title | Page |
---|---|---|
WEPFI086 | Normal Conducting Radio Frequency X-band Deflecting Cavity Fabrication, Validation and Tuning | 2899 |
|
||
An X-band Traveling wave Deflector mode cavity (XTD) has been developed, fabricated, tuned and characterized by Radiabeam Technologies to perform longitudinal measurement of the sub-picosecond ultra-relativistic electron beams. The device is optimized for the 100 MeV electron beam parameters at the Accelerator Test Facility (ATF) at Brookhaven National Laboratory, and is scalable to higher energies. The XTD is designed to operate at 11.424 GHz, and features short filling time, femtosecond resolution, and a small footprint. RF design, structure fabrication, cold testing and tuning results are presented. | ||
WEPFI088 | High-power Tests of an Ultra-high Gradient Compact S-band (HGS) Accelerating Structure | 2902 |
|
||
RadiaBeam Technologies reports on the RF design, fabrication and high-power tests of a ultra-high gradient S-Band accelerating structure (HGS) operating in the pi-mode at 2.856 GHz. The compact HGS structure offers a drop-in replacement for conventional S-Band linacs in research and industrial applications such as drivers for compact light sources, medical and security systems. The electromagnetic design (optimization of the cell shape in order to maximize RF efficiency and minimize surface fields at very high accelerating gradients) has been carried out with the codes HFSS and SuperFish while the thermal analysis has been performed by using the code ANSYS. The high-power conditioning was carried out at Lawrence Livermore National Laboratory (LLNL). | ||
WEPFI089 | High Gradient Normal Conducting Radio-frequency Photoinjector System for Sincrotrone Trieste | 2905 |
|
||
Radiabeam Technologies, in collaboration with UCLA, presents the development of a high gradient normal conducting radio frequency (NCRF) 1.6 cell photoinjector system for the Sincrotrone Trieste facility. Designed to operate with a 120MV/m accelerating gradient, this single feed, fat lipped racetrack coupler design is modeled after the LCLS photoinjector with a novel demountable cathode which permits cost effective cathode exchange. Full overview of the project to date and installation at Sincrotrone Trieste will be discussed along with basic, design, engineering and manufacturing. | ||
THPWA051 | Compact, Inexpensive X-band Linacs as Radioactive Isotope Source Replacements | 3746 |
|
||
Funding: Work supported by DNDO Phase II SBIR HSHQDC-10-C-00148 and DOE Phase II SBIR DE- SC0000865. Radioisotope sources are commonly used in a variety of industrial and medical applications. The US National Research Council has identified as a priority the replacement of high-activity sources with alternative technologies, due to the risk of accidents and diversion by terrorists for use in Radiological Dispersal Devices (“dirty bombs”). RadiaBeam Technologies is developing novel, compact, inexpensive linear accelerators for use in a variety of such applications as cost-effective replacements. The technology is based on the MicroLinac (originally developed at SLAC), an X-band linear accelerator powered by an inexpensive and commonly available magnetron. Prototypes are currently under construction. This paper will describe the design, engineering, fabrication and testing of these linacs at RadiaBeam. Future development plans will also be discussed. |
||