Author: Huang, D.-G.
Paper Title Page
WEPPD045 An Application of Multi-stage Adjustable Shock Absorbers for the Girders of Storage Ring in Taiwan Photon Source 2615
 
  • C.-S. Lin, J.-R. Chen, M.L. Chen, H.C. Ho, K.H. Hsu, D.-G. Huang, C.K. Kuan, W.Y. Lai, C.J. Lin, H.M. Luo, S.Y. Perng, P.L. Sung, Y.L. Tsai, T.C. Tseng, H.S. Wang, M.H. Wu
    NSRRC, Hsinchu, Taiwan
  • D.-Y. Chiang
    NCKU, Tainan city, Taiwan
 
  Beam stability is a major concern for the operation of the Taiwan Photon Source (TPS). One of the many factors to instability of electron beam is mechanical vibration of the accelerator components. The TPS uses steel girders to support the magnets and vacuum chambers in the storage ring. Three pedestal and six mover assemblies support the girders. Multi-stage adjustable shock absorbers are designed for passive vibration damping, and presently installed between the girders and the pedestals. Through adjusting the amount of hydraulic fluid which bypasses the damping passage between two hydraulic chambers, the desired damping coefficient of the damping absorbers can be achieved. Experimental results of modal testing presented in this paper show that the multi-stage adjustable damping absorbers under the assembly of the girders reduced the level of girder vibration.  
 
WEPPP088 Auto-alignment System and CalibrationPprocedure in TPS Girder System 2918
 
  • W.Y. Lai, J.-R. Chen, M.L. Chen, H.C. Ho, K.H. Hsu, D.-G. Huang, C.K. Kuan, C.-S. Lin, C.J. Lin, H.M. Luo, S.Y. Perng, P.L. Sung, Y.L. Tsai, T.C. Tseng, H.S. Wang, M.H. Wu
    NSRRC, Hsinchu, Taiwan
 
  The TPS (Taiwan photon source) project is under construction and will be finished in the December 2012. Considering the floor’s deformation with time and frequent earthquakes at Taiwan, the survey and alignment procedure should be taken quite often. For dealing with these difficulties and improving accuracy of girder’s position, a highly accurate auto-tuning girders system was designed to accomplish the alignment tasks. There are two cells of TPS girders and varied sensor modulus set up for testing the auto-tuning system. The adjustment of the system converges to less than 6um, and the repeatability of the testing is under 10 um. For improving the accuracy of girders position, that is critical thing to make sure all the calibration of sensors modulus correctly and accurately. The calibration procedure about sensor modular and testing results is described in this paper.  
 
THPPD061 Optimal Design for Resonant Power Transformer 3650
 
  • C.-Y. Liu, D.-G. Huang, J.C. Huang
    NSRRC, Hsinchu, Taiwan
 
  The energy and dc to dc conversion of the resonant transformer are required to achieve optimal design and working condition of the resonant region frequency. To meet this requirement, the core loss will be checked first by data book for calculation. Using a reliable precise instrument is needed to scan the resonant cure of the resonant transformer as we designed the resonant cure. We calculated the conduction loss in second design step. We design a resonant transformer which the conduction loss equal core loss does not meet optima design, because the core loss is very high when the transformer works in resonant frequency. Thus, we only reduce the conduction loss is optima design aspect.