Author: Lyapin, A.
Paper Title Page
MOPC27 Cavity Beam Position Monitor System for ATF2 120
 
  • S.T. Boogert
    Royal Holloway, University of London, Surrey, United Kingdom
  • S.T. Boogert, F.J. Cullinan, Y.I. Kim, A. Lyapin, J. Snuverink
    JAI, Egham, Surrey, United Kingdom
  • T. Tauchi, N. Terunuma, J. Urakawa
    KEK, Ibaraki, Japan
  • G.R. White
    SLAC, Menlo Park, California, USA
 
  The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C- and S- band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, including a study of the CBPM performance over a three week period, including systematic effects such as charge, bunch length and beam offset dependence. The BPM system is routinely used for beam based alignment, wakefield kick measurements and dispersion measurements, the operational experience and example measurements are also reported.  
 
TUPC19 First Beam Tests of a Prototype Cavity Beam Position Monitor for the CLIC Main Beam 411
 
  • F.J. Cullinan, S.T. Boogert, A. Lyapin, J.R. Towler
    JAI, Egham, Surrey, United Kingdom
  • W. Farabolini, T. Lefèvre, L. Søby, M. Wendt
    CERN, Geneva, Switzerland
 
  Beam position monitors (BPMs) throughout the CLIC (Compact Linear Collider) main linac and beam delivery system must routinely operate at 50 nm resolution and be able to make multiple position measurements within a single 156 ns long bunch train. A prototype cavity beam position monitor, designed to demonstrate this performance, has been tested on the probe beamline of CTF3 (the CLIC Test Facility). Sensitivity measurements of the dipole mode position cavity and of the monopole mode reference cavity have been made. The characteristics of signals from short and long bunch trains and the dominant systematic effects have also been studied.  
 
TUPC20 Technologies and R&D for a High Resolution Cavity BPM for the CLIC Main Beam 415
 
  • J.R. Towler, T. Lefèvre, L. Søby, M. Wendt
    CERN, Geneva, Switzerland
  • S.T. Boogert, F.J. Cullinan, A. Lyapin
    JAI, Egham, Surrey, United Kingdom
 
  The Main Beam (MB) LINAC of the Compact Linear Collider (CLIC) requires a beam orbit measurement system with a high spatial (50 nm) and high temporal (50 ns) resolution to resolve the beam position within the 156 ns long bunch train, traveling on an energy-chirped, minimum dispersive trajectory. A 15 GHz prototype cavity BPM has been commissioned in the probe beam-line of the CTF3 CLIC Test Facility. The performance and technical details of this prototype installation are discussed in this paper, including the 15 GHz analog down-converter, the data acquisition and the control electronics and software. An R&D outlook is given for the next steps, which requires a system of 3 cavity BPMs to investigate the full resolution potential.  
 
TUPC22 Cavity Beam Position Monitor in Multiple Bunch Operation for the ATF2 Interaction Point Region 419
 
  • Y.I. Kim, D.R. Bett, N. Blaskovic Kraljevic, S.T. Boogert, P. Burrows, G.B. Christian, M.R. Davis, A. Lyapin, C. Perry
    JAI, Oxford, United Kingdom
  • J.C. Frisch, D.J. McCormick, J. Nelson, G.R. White
    SLAC, Menlo Park, California, USA
  • Y. Honda, T. Tauchi, N. Terunuma, J. Urakawa
    KEK, Ibaraki, Japan
 
  The Accelerator Test Facility 2 (ATF2) at KEK, Japan, is a scaled test beam line for the international linear collider (ILC) final focus system. There are two goals: firstly, to demonstrate focusing to 37 nm vertical beam size; secondly, to achieve a few nanometer level beam orbit stability at the focus point (the Interaction Point (IP)) in the vertical plane. High-resolution beam position monitors around the IP area (IPBPMs) have been developed in order to measure the electron beam position in that region with a resolution of a few nanometers in the vertical plane. Currently, the standard operation mode at ATF2 is single bunch, however, multiple bunch operation with a bunch spacing similar to the one foreseen for the ILC (around 300 ns) is also possible. IPBPMs have a low Q value resulting in a decay time of about 30 ns, and so should be able to measure the beam position of individual bunches without any significant performance degradation. The IPBPMs in the ATF2 extraction beam line have been tested in multibunch regime. This paper analyses the signals, processing methods and results for this mode.  
poster icon Poster TUPC22 [1.050 MB]