Author: Shirai, T.
Paper Title Page
MOPA02 Beam Alignment Procedure for Scanned Ion-Beam Therapy 36
 
  • Y. Saraya, T. Furukawa, Y. Hara, K. Mizushima, K. Noda, N. S. Saotome, T. Shirai, R. Tansho
    NIRS, Chiba-shi, Japan
  • E. Takeshita
    Kanagawa Cancer Center, Ion-beam Radiation Oncology Center in Kanagawa, Kanagawa, Japan
 
  It's important to control the beam position for the 3D pencil-beam scanning because the position accuracy of the beam has a serious matter on the alignment of the irradiation field. In order to suppress this matter, we have been developed a simple procedure for the beam tuning. The fluctuation of the beam position is tuned with the steering magnets (ST) and the fluorescent screen monitors (SCN). At first, the beam positions are measured by two SCN and the kick angles of two ST are calculated using deviates from the center of the beam position measured by SCN and the transfer matrix. After the tuning, the beam position at the isocenter is checked on the verification system for the alignment of the beam consists of the SCN and the iron sphere phantom. If the beam position is deviated from the center, one of ST placed on most downstream of the beam transport line will be corrected. These adjustments are iterated until the deviation for all energies of the beam are within 0.5 mm. We have been performed the beam commissioning using our procedure in Kanagawa Cancer Center. In this presentation, we will report on the result of these measurements.  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)  
 
FRM1C01 Present Status of a Superconducting Rotating-Gantry for Carbon Therapy 288
 
  • Y. Iwata, T. Furukawa, Y. Hara, S. Matsuba, S. Mori, K. Noda, S. Sato, T. Shirai, K. Shoda, R. Tansho
    NIRS, Chiba-shi, Japan
  • N. Amemiya
    Kyoto University, Kyoto, Japan
  • H. Arai, T. Fujimoto
    AEC, Chiba, Japan
  • T.F. Fujita, K. Mizushima, Y. Saraya
    National Institute of Radiological Sciences, Chiba, Japan
  • Y. Nagamoto, T. Orikasa, S. Takayama
    Toshiba, Yokohama, Japan
  • T. Ogitsu
    KEK, Ibaraki, Japan
 
  A superconducting rotating-gantry for carbon therapy is being developed. This isocentric rotating gantry can transport carbon ions with the maximum energy of 430 MeV/u to an isocenter with irradiation angles of over 0-360 degrees, and is further capable of performing three-dimensional raster-scanning irradiation. The combined-function superconducting magnets were employed for the rotating gantry. The superconducting magnets with optimized beam optics allowed a compact gantry design with a large scan size at the isocenter; the length and the radius of the gantry are approximately 13 and 5.5 m, respectively, which are comparable to those for the existing proton gantries. Furthermore, the maximum scan size at the isocenter is calculated to be as large as approximately 200 mm square for heavy-ion beams at the maximum energy of 430 MeV/u. A construction and installation of the superconducting gantry is in progress, and beam commissioning will begin from this autumn. We will present a status of the superconducting rotating-gantry.  
slides icon Slides FRM1C01 [40.189 MB]  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)