TUPA04 sFLASH - Present Status and Commisioning Results 194
 
  • V. Miltchev, S. Ackermann, A. Azima, J. Bödewadt, F. Curbis, M. Drescher, E. Hass, Th. Maltezopoulos, M. Mittenzwey, J. Rönsch-Schulenburg, J. Roßbach, R. Tarkeshian
    Uni HH, Hamburg, Germany
  • H. Delsim-Hashemi, K. Honkavaara, T. Laarmann, H. Schlarb, S. Schreiber, M. Tischer
    DESY, Hamburg, Germany
  • R. Ischebeck
    Paul Scherrer Institut, Villigen, Switzerland
 
  The free-electron laser in Hamburg (FLASH) was previously being operated in the self-amplified spontaneous emission (SASE) mode, producing photons in the XUV wavelength range. Due to the start-up from noise the SASE-radiation consists of a number of uncorrelated modes, which results in a reduced coherence. One option to simultaneously improve both the coherence and the synchronisation between the FEL-pulse and an external laser is to operate FLASH as an amplifier of a seed produced using high harmonics generation (HHG). An experimental set-up - sFLASH, has been installed to test this concept for the wavelengths below 40 nm. The sFLASH installation took place during the planed FLASH shutdown in the winter of 2009/2010. The technical commissioning, which began in the spring of 2010, has been followed by FEL-characterization and seeded-FEL commissioning in 2011. In this contribution the present status and the sFLASH commissioning results will be discussed.  
 
THPB06 Coherent Terahertz Radiation Monitors for Multiple Spectral Bands 572
 
  • R. Ischebeck, G.L. Orlandi, P. Peier, V. Schlott, B. Smit, C. Vicario, C. Zimmerli
    Paul Scherrer Institut, Villigen, Switzerland
  • C. Gerth
    DESY, Hamburg, Germany
 
  The SwissFEL Injector Test Facility is destined for demonstrating electron beam parameters that are suitable for FEL operation. Of particular interest is the on-line measurement of longitudinal phase space properties, as this provides insight into the bunch compression process. The spectral distribution of diffraction radiation offers a robust way to assess bunch length and longitudinal profile. The bunch length at the SwissFEL Injector Test Facility can be varied by changing the photocathode laser. Diffraction radiation is emitted as the electron bunches pass through a hole in a titanium foil. The emitted Terahertz radiation has been simulated by the code THz Transport, and the propagation to the detectors has been modeled.  
 
THPB30 SwissFEL Injector Test Facility – Test and Plans 625
 
  • M. Pedrozzi, M. Aiba, S. Bettoni, B. Beutner, A. Falone, R. Ganter, R. Ischebeck, F. Le Pimpec, G.L. Orlandi, E. Prat, S. Reiche, T. Schietinger, A. Trisorio, C. Vicario
    Paul Scherrer Institut, Villigen, Switzerland
 
  In August 2010 the Paul Scherrer Institute inaugurated the SwissFEL Injector test facility as a first step toward the Swiss hard X-ray FEL planned at PSI. The main purpose of the facility is to demonstrate and consolidate the generation of high-brightness beam as required to drive the 6 GeV SwissFEL accelerator. Additionally the injector serves as a platform supporting development and test of accelerator components/systems and optimization procedures foreseen for SwissFEL. In this paper we report on the present status of the commissioning with some emphasis on emittance measurements and component performances. The scientific program and long-term plans will be discussed as well.  
 
FROA4 Response Matrix of Longitudinal Instrumentation in SwissFEL 652
 
  • R. Ischebeck, B. Beutner, R. Kalt, P. Peier, S. Reiche, T. Schilcher, V. Schlott
    Paul Scherrer Institut, Villigen, Switzerland
 
  Several sources of jitter and drift affect the longitudinal phase space dynamics of SwissFEL. To evaluate how drifts can be identified and corrected through appropriate diagnostics and beam-based feedbacks, the response matrix of possible longitudinal diagnostics on laser and RF stability is modeled. To this intent, photocathode laser intensity, laser arrival time, RF phases and RF amplitudes are individually varied in an ELEGANT model, and the expected response of on-line diagnostics on the simulated bunches is evaluated. By comparing the slope of the response to the expected resolution of the instrumentation, suitable monitors can be selected for a feedback.  
slides icon Slides FROA4 [2.837 MB]