Keyword: impedance
Paper Title Other Keywords Page
MOP028 Design of 5.8 MHz RF Electrode for AMS Cyclotron cyclotron, cavity, acceleration, tandem-accelerator 94
 
  • D.H. Ha, J.-S. Chai, Kh.M. Gad, M. Ghergherehchi, H.S. Kim, J.C. Lee, H. Namgoong
    SKKU, Suwon, Republic of Korea
 
  Accelerator Mass Spectrometry (AMS) is a powerful method for separating isotopes, and electrostatic tandem accelerators are widely used for AMS. Sungkyunkwan University is developing AMS that can be used in a smaller space based on cyclotron. Unlike conventional cyclotrons used in PET or proton therapy, cyclotron-based AMS provides high turn number and high resolution. In this study, we proposed a cavity with a frequency of 5.8 MHz and an accelerating voltage of 300 V to accelerate the particles in the cyclotron. The proposed cavity was designed as an electrode and verified by CST Microwave studio.  
poster icon Poster MOP028 [1.078 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-Cyclotrons2019-MOP028  
About • paper received ※ 15 September 2019       paper accepted ※ 24 September 2019       issue date ※ 20 June 2020  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOP030 RF measurement of SKKUCY-10 RF Cavity for Impedance Matching cavity, coupling, cyclotron, beam-loading 100
 
  • J.C. Lee, J.-S. Chai, Kh.M. Gad, M. Ghergherehchi, D.H. Ha, H.S. Kim, H. Namgoong
    SKKU, Suwon, Republic of Korea
 
  Funding: Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning through the National Research Foundation of Korea
The 10 MeV cyclotron was designed for next version in Sungkyunkwan University, after the SKKUCY-9 had developed for medical application for PET. The RF cavity, which generates the electric field in cyclotron, was designed based on a half-wavelength resonator and optimized to improve the unloaded quality factor (Q0). The design specifications of RF cavity were resonance frequency 83.2 MHz, Q0 5830 and Dee voltage 40 kV with geometrical values resonator length 560 mm, Dee angle 35° and Stem radius 16 mm. The RF cavity of the SKKUCY-10 was fabricated and installed inside the electromagnet, and RF characteristics were measured with a network analyzer. The RF coupling coefficient and characteristic impedance for desired condition were selected at 1.08 and 52 ’, respectively. The RF coupling coefficient and characteristic impedance were measured 0.8-1.2, 52-49 ’ according to temperature as 15-21°C. The power coupler was checked for optimization of RF coupling coefficient and characteristic impedance, and the results show good agreement with simulated and measured data.
 
poster icon Poster MOP030 [1.665 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-Cyclotrons2019-MOP030  
About • paper received ※ 15 September 2019       paper accepted ※ 23 June 2020       issue date ※ 20 June 2020  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)