Paper | Title | Page |
---|---|---|
TUPCAV015 | Performance of a Low Frequency QWR-Based SRF Gun | 472 |
|
||
Funding: This work was supported by the U.S. Department of Energy, Office of Nuclear Physics, under Contract No. DE-AC02-06CH11357. Superconducting radio-frequency (SRF) electron guns are generally considered to be an effective way of producing beams with high brightness and high repetition rates (or continuous wave). In this work, the 199.6 MHz quarter wave resonator (QWR)-based Wisconsin Free Electron Laser (WiFEL) superconducting electron gun was recently refurbished and tested at Argonne (ANL). The field performance of the e-gun was fully characterized. During this time, multipacting (MP) conditioning was performed for over 20 hours to overcome the hard MP barrier observed in the accelerating voltage range of 8 to 40 kV; the presence of multipacting is expected to operationally important for future e-guns. Here we simulated and studied the effect using CST* Microwave Studio and Particle Studio and compare with the measured data. * CST Studio Suite, version 2020, https://www.cst.com. |
||
![]() |
Poster TUPCAV015 [4.874 MB] | |
DOI • | reference for this paper ※ doi:10.18429/JACoW-SRF2021-TUPCAV015 | |
About • | Received ※ 21 June 2021 — Revised ※ 20 December 2021 — Accepted ※ 22 February 2022 — Issue date ※ 23 March 2022 | |