We presented the RF measurement on a 1.3 GHz single cell cavity fabricated at KEK using large grain ingot niobium with RRR=107. The cavity reached to 35 MV/m with Q0 = 2.0×10zEhNZeHn at 2.0 K, record performance on the cavity made from medium purity ingot niobium. The cavity was cool down with different temperature gradient along the cavity axis in order to understand the flux expulsion mechanism when the cavity does through the superconducting transition and effect of trap residual magnetic field on the residual resistance. The measurement showed the excellent flux expulsion with the flux trapping sensitivity of 0.29 nΩ/mG for electro polished surface and 0.44 nΩ/mG for cavity followed by low temperature baking at 120°C for 12 hours.
We acknowledge KEK for sending this cavity for evaluations.
 