Author: Klemz, G.
Paper Title Page
TUP100 Thermal Load Studies on the Photocathode Insert with Exchangeable Plug for the BERLinPro SRF-Photoinjector 705
SUSP039   use link to see paper's listing under its alternate paper code  
 
  • J. Kühn, N. Al-Saokal, M. Bürger, M. Dirsat, A. Frahm, A. Jankowiak, T. Kamps, G. Klemz, S. Mistry, A. Neumann, H. Plötz
    HZB, Berlin, Germany
 
  For the operation of an SRF photoinjector a well-functioning and efficient cooling system of the photocathode is necessary. A test experiment was set up of the photocathode cooling system based on the original components, which we call thermal contact experiment (TCX). We present the results of our thermal load studies on the photocathode insert with exchangeable photocathode plug. The goal was to test all components before they are installed in the cold string of the BERLinPro SRF-Photoinjector to ensure the operation of very sensitive semiconductor photocathodes. The tests include the investigation of the cooling performance, the thermal load management and the mechanical stability of the photocathode insert.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2019-TUP100  
About • paper received ※ 23 June 2019       paper accepted ※ 30 June 2019       issue date ※ 14 August 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)