Paper |
Title |
Page |
TUPB072 |
Investigation of BCP Parameters for Mastery of SRF Cavity Treatment |
558 |
|
- F. Éozénou
CEA/DSM/IRFU, France
- E. Cenni, G. Devanz, T. Percerou, Th. Proslier, C. Servouin
CEA/DRF/IRFU, Gif-sur-Yvette, France
- M.L.L. Nghiem
UPMC, Paris, France
|
|
|
Mastery of Standard Buffered Chemical Polishing (with mixture of hydrofluoric, nitric and phosphoric acids) is of paramount importance for the treatment of SRF resonators with complex geometry has IFMIF half-wave resonators, in order to control accurately their frequency evolution. Furthermore, strong and unexpected asymmetry in removals has recently been observed after BCP treatment of ESS-medium beta resonators. The goal of this study is to investigate accurately influence of parameters such as surface geometry and orientation, acid temperature, agitation and their coupling on the removal rate. We will also focus on the influence of by-products such has NOx on kinetics. The mixture used is HF(40%)- HNO3(65%)-H3PO4(85%) with ratio 1-1-2.4.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-SRF2017-TUPB072
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPB093 |
Nb Single-cell Cavity Vertical Electro-polishing with Ninja Cathode and Evaluation of its Accelerating Gradient |
612 |
|
- K.N. Nii, V. Chouhan, Y.I. Ida, T.Y. Yamaguchi
MGH, Hyogo-ken, Japan
- P. Carbonnier, Y. Gasser, L. Maurice
CEA/IRFU, Gif-sur-Yvette, France
- F. Éozénou, C. Servouin
CEA/DSM/IRFU, France
- H. Hayano, S. Kato, H. Monjushiro, T. Saeki, M. Sawabe
KEK, Ibaraki, Japan
- Th. Proslier
CEA/DRF/IRFU, Gif-sur-Yvette, France
|
|
|
Marui Galvanizing Co. Ltd. has been improving Vertical Electro-Polishing (VEP) technology for Nb superconducting RF cavity in collaboration with KEK. In this collaboration, we developed a unique cathode namely Ninja cathode for VEP treatment of Nb cavities. We have already reported that longitudinal symmetry in niobium removal and surface state of a single cell cavity were improved after VEP using the Ninja cathode. In this article, we report a result of accelerating gradient evaluation for 1.3 GHz single cell RF cavity after VEP with Ninja cathode in collaboration with KEK and CEA Saclay.
|
|
|