Author: Bing, B.
Paper Title Page
MOPB054 Design of Fundamental Power Coupler for High Intensity Heavy-ion Accelerator 183
 
  • B. Bing, T.M. Huang, Q. Ma, F. Meng, W.M. Pan
    IHEP, Beijing, People's Republic of China
  • K.X. Gu
    Institute of High Energy Physics (IHEP), Chinese Academy of Sciences, Beijing, People's Republic of China
 
  A single-window coaxial coupler at warm has been designed for high intensity heavy-ion accelerator. The coupler is designed to handle 100 kW CW power of 325 MHz and is currently being fabricated. T-bend transition and doorknob have been taken into account. The length of the T-bend short circuit is sensitive to S parameters and contributes to the online adjustment of VSWR in RF conditioning. The doorknob type is adopted to realize the transition from a half-height WR 2300 waveguide to a coaxial line ended with a coupling antenna. This paper describes the RF design, thermal stress and heat load analysis of the coupler as well as multipacting simula-tions.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2017-MOPB054  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPB070 The Improvement of the Power Coupler for CADS SC Spoke Cavities 220
 
  • T.M. Huang, B. Bing, X. Chen, H.Y. Lin, Q. Ma, F. Meng, W.M. Pan, G.W. Wang
    IHEP, Beijing, People's Republic of China
  • K.X. Gu
    Institute of High Energy Physics (IHEP), Chinese Academy of Sciences, Beijing, People's Republic of China
 
  Twenty superconducting spoke cavities mounted in three cryomodules (CM1, CM2 and CM4) were in-stalled in the CADS, a test facility of 10 mA, 25 MeV CW proton linac. Each cavity was equipped with one coaxial type fundamental power coupler (FPC). Fatal window crack was observed during the test cryomod-ule (TCM) commissioning. A series of experiments were subsequently implemented and eventually at-tributed the window crack to the electron bombard-ment from cavity field emission (FE). Improvements covering the coupler cleaning and assembly proce-dure, the structure and position modifications were thus implemented, aiming to reduce the cavity contam-ination and avoid the window damaged by cavity FE electrons. This paper will describe how the coupler window damaged by cavity field emission and the improve-ments for cure. In addition, the performances of FPCs for CM1, CM2 and CM4 were compared.  
poster icon Poster MOPB070 [0.613 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2017-MOPB070  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)