Author: Bekhterev, V.
Paper Title Page
MOPSA50 Axial Injection System of DC140 Cyclotron of FLNR JINR 209
 
  • N.Yu. Kazarinov, V. Bekhterev, G.G. Gulbekyan, I.A. Ivanenko, I.V. Kalagin, S.V. Mitrofanov, N.F. Osipov, V.A. Semin
    JINR, Dubna, Moscow Region, Russia
  • V.I. Lisov
    JINR/FLNR, Moscow region, Russia
 
  Flerov Laboratory of Nuclear Reaction of Joint Institute for Nuclear Research continues the works under creating of FLNR JINR Irradiation Facility based on the cyclotron DC140. The facility will have three experimental beam lines for SEE testing of microchips, for production of track membranes and for solving of applied physics problems. The injection into cyclotron will be realized from the external room temperature 18 GHz ECR ion source. The systems of DC140 cyclotron such as axial injection, main magnet, RF- and extraction systems and beam lines are the reconstruction of the DC72 cyclotron ones. The acceleration in DC140 cyclotron is carried out for two values of harmonic number h = 2,3 of heavy ions with mass-to-charge ratio A/Z within two intervals 5 - 5.5 and 7.5 - 8.25 up to two fixed energies 2.124 and 4.8 MeV per unit mass, correspondingly. The intensity of the accelerated ions will be about 1 pmcA for light ions (A<86) and about 0.1 pmcA for heavier ions (A>132). The design of the axial injection system of the DC140 cyclotron is presented in this report.  
DOI • reference for this paper ※ doi:10.18429/JACoW-RuPAC2021-MOPSA50  
About • Received ※ 27 August 2021 — Revised ※ 07 September 2021 — Accepted ※ 10 September 2021 — Issued ※ 23 October 2021
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)