Author: Sedlyarov, I.K.
Paper Title Page
THCDMH05 New RF System for VEPP-5 Damping Ring 113
 
  • G.Y. Kurkin, Y.A. Biryuchevsky, E. Kenzhebulatov, A.A. Kondakov, A,Yu. Martynovsky, S.V. Motygin, V.N. Osipov, A.M. Pilan, E. Rotov, I.K. Sedlyarov, A.G. Tribendis
    BINP SB RAS, Novosibirsk, Russia
 
  The VEPP-5 injection complex serves to obtain high-intensity electron and positron bunches for injection into colliders of the Institute of Nuclear Physics SB RAS. The old RF System operated at 700 MHz - the 64-the harmonic of the revolution frequency. Due to the large beam length from LINAC up to 70% of the particles were lost during injection. Therefore, in 2015, the decision was made to install into the ring the new RF cavity operated at the first harmonic of the ring revolution frequency of 10.94 MHz. To reduce the geometric dimensions, ferrites were used in the cavity. The RF cavity was manufactured, an RF power amplifier and a new RF control system were prepared. After testing the RF system at the stand, in August 2017 the RF cavity was installed instead of the former 700 MHz cavity. The new RF system is now in operation since September 2017. The paper presents main features of the cavity design and fabrication. RF power amplifier and operation of the control system are described.  
slides icon Slides THCDMH05 [10.410 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-RUPAC2018-THCDMH05  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPSC53 Test Stand Results of CW 100 mA Electron RF Gun for Novosibirsk ERL FEL 507
 
  • V. Volkov, V.S. Arbuzov, E. Kenzhebulatov, E.I. Kolobanov, A.A. Kondakov, E.V. Kozyrev, I.V. Kuptsov, G.Y. Kurkin, S.V. Motygin, A.A. Murasev, V.K. Ovchar, V.M. Petrov, A.M. Pilan, V.V. Repkov, M.A. Scheglov, I.K. Sedlyarov, S.S. Serednyakov, O.A. Shevchenko, S.V. Tararyshkin, A.G. Tribendis, N.A. Vinokurov
    BINP SB RAS, Novosibirsk, Russia
  • E.V. Kozyrev, S.S. Serednyakov, N.A. Vinokurov
    NSU, Novosibirsk, Russia
  • A.G. Tribendis
    NSTU, Novosibirsk, Russia
  • N.A. Vinokurov
    KAERI, Daejon, Republic of Korea
  • N.A. Vinokurov
    University of Science and Technology of Korea (UST), Daejeon, Republic of Korea
 
  Continuous wave (CW) 100 mA electron rf gun for injecting the high-quality 300-400 keV electron beam in Novosibirsk Energy Recovery Linac (ERL) and driving Free Electron Laser (FEL) was developed, built, and commissioned at BINP SB RAS. The RF gun consists of normal conducting 90 MHz rf cavity with a gridded thermionic cathode unit. Bench tests of rf gun is confirmed good results in strict accordance with our numerical calculations. The gun was tested up to the design specifications at a test bench that includes a diagnostics beam line. The rf gun stand testing showed reliable work, unpretentious for vacuum conditions and stable in long-term operation. The design features of different components of the rf gun are presented. Preparation and commissioning experience is discussed. The latest beam results are reported.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-RUPAC2018-THPSC53  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)