Author: Strokach, A.P.
Paper Title Page
WEX03 Production of Accelerating Equipment for Nuclear Medicine in NIIEFA. Potentialities and Prospects 125
 
  • M.F. Vorogushin, Yu.N. Gavrish, A.P. Strokach
    NIIEFA, St. Petersburg, Russia
 
  The D.V.Efremov Institute (NIIEFA) is the leader in Russia in designing and manufacturing of the accelerating equipment for medicine. About one hundred of linear accelerators for the beam therapy and more than forty cyclotrons for production of radiopharmaceuticals have been designed, manufactured and delivered to clinics of Russia and some foreign countries. The equipment designed and manufactured in NIIEFA in its technical characteristics is on a par with foreign analogs and sufficiently cheaper in expenditures for personnel training, hardware and software compatibility, warranty and post-warranty service, delivery of spare parts and updating. In accordance with Federal Targeted Programs on the development of medical and pharmaceutical industries up to 2020, the production facilities, material and technical resources have been prepared for the organization of serial production of cyclotrons and gamma tomographs.  
slides icon Slides WEX03 [0.901 MB]  
 
WECA11 CC-18/9M Cyclotron System 149
 
  • A.P. Strokach, M.A. Emeljanov, A.V. Galchuck, Yu.N. Gavrish, S.V. Grigorenko, V.I. Grigoriev, M.L. Klopenkov, A.N. Kuzhlev, V.G. Mudroliubov, G.V. Muraviov, V.I. Nikishkin, V.I. Ponomarenko, Yu.I. Stogov, S.S. Tsygankov, O.L. Veresov
    NIIEFA, St. Petersburg, Russia
 
  The СС-18/9M cyclotron system has been designed, manufactured and delivered to NIITFA, Moscov. The system consists of an updated cyclotron and a targets system. The cyclotron is intended to produce proton and deuteron beams with an energy of 12-18/6-9 MeV and current up to 150/70 mkA. For this purpose, a shielding-type electromagnet and a resonance system have been afresh designed. The target system for the production of F-18 and C-11 radionuclides has been designed in NIIEFA for the first time.  
slides icon Slides WECA11 [0.547 MB]  
 
WEPSB11 Test Results of 433 MHz Deuteron Linac (RFQ) 177
 
  • Y.A. Svistunov, S.V. Grigorenko, A.N. Kuzhlev, A.K. Liverovskij, I.I. Mezhov, A.A. Ryaskov, A.P. Strokach, V.F. Tsvetkov, O.L. Veresov, Yu. Zuev
    NIIEFA, St. Petersburg, Russia
 
  The results of bench tests of the high frequency deuteron accelerator (RFQ) with output energy of 1 MeV and operating frequency of 433 MHz are presented. There are briefly discussed RFQ construction and assembling, rf system, issues of tuning and measuring of electrodynamical characteristics of RFQ. Output data obtained under accelerated beam operation with foil monitor and Beryllium target are given.