A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Varnasseri, S.

Paper Title Page
MOPAN048 Design of Injection Pulsed Magnets for SESAME Ring 266
 
  • S. Varnasseri, M. M. Shehab, G. Vignola
    SESAME, Amman
 
  In this paper the SESAME storage ring injection pulsed magnet system is described. The injection process in the SESAME storage ring requires septum and kicker magnets. In this paper we discuss the geometrical and magnetic field requirements for septum and kicker magnets and present the results obtained from magnetic field analysis and also the optimization of titanium coating for the injection kicker chambers. The final specification for thin septum and injection kickers are also presented.