A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Smith, S.

Paper Title Page
WEOBAB01 Electromagnetic Background Tests for the ILC Interaction Point Feedback System 1970
 
  • P. Burrows, G. B. Christian, C. I. Clarke, B. Constance, A. F. Hartin, H. D. Khah, C. Perry, C. Swinson, G. R. White
    JAI, Oxford
  • R. Arnold, S. Molloy, S. Smith, G. R. White, M. Woods
    SLAC, Menlo Park, California
  • A. Kalinin
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire
 
  We present results obtained with the T-488 experiment at SLAC Endstation A (ESA). A material model of the ILC extraction-line design was assembled and installed in ESA. The module includes materials representing the mask, beamline calorimeter, and first extraction quadrupole, encompassing a stripline interaction-point feedback system beam position monitor (BPM). The SLAC high-energy electron beam was used to irradiate the module in order to mimic the electromagnetic (EM) backgrounds expected in the ILC interaction region. The impact upon the performance of the feedback BPM was measured, and compared with detailed simulations of its expected response.  
slides icon Slides  
WEOCAB01 Design of the Beam Delivery System for the International Linear Collider 1985
 
  • A. Seryi, J. A. Amann, R. Arnold, F. Asiri, K. L.F. Bane, P. Bellomo, E. Doyle, A. F. Fasso, L. Keller, J. Kim, K. Ko, Z. Li, T. W. Markiewicz, T. V.M. Maruyama, K. C. Moffeit, S. Molloy, Y. Nosochkov, N. Phinney, T. O. Raubenheimer, S. Seletskiy, S. Smith, C. M. Spencer, P. Tenenbaum, D. R. Walz, G. R. White, M. Woodley, M. Woods, L. Xiao
    SLAC, Menlo Park, California
  • I. V. Agapov, G. A. Blair, S. T. Boogert, J. Carter
    Royal Holloway, University of London, Surrey
  • M. Alabau, P. Bambade, J. Brossard, O. Dadoun
    LAL, Orsay
  • M. Anerella, A. K. Jain, A. Marone, B. Parker
    BNL, Upton, Long Island, New York
  • D. A.-K. Angal-Kalinin, C. D. Beard, J.-L. Fernandez-Hernando, P. Goudket, F. Jackson, J. K. Jones, A. Kalinin, P. A. McIntosh
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire
  • R. Appleby
    UMAN, Manchester
  • J. L. Baldy, D. Schulte
    CERN, Geneva
  • L. Bellantoni, A. I. Drozhdin, V. S. Kashikhin, V. Kuchler, T. Lackowski, N. V. Mokhov, N. Nakao, T. Peterson, M. C. Ross, S. I. Striganov, J. C. Tompkins, M. Wendt, X. Yang
    Fermilab, Batavia, Illinois
  • K. Buesser
    DESY, Hamburg
  • P. Burrows, G. B. Christian, C. I. Clarke, A. F. Hartin
    OXFORDphysics, Oxford, Oxon
  • G. Burt, A. C. Dexter
    Cockcroft Institute, Warrington, Cheshire
  • J. Carwardine, C. W. Saunders
    ANL, Argonne, Illinois
  • B. Constance, H. Dabiri Khah, C. Perry, C. Swinson
    JAI, Oxford
  • O. Delferriere, O. Napoly, J. Payet, D. Uriot
    CEA, Gif-sur-Yvette
  • C. J. Densham, R. J.S. Greenhalgh
    STFC/RAL, Chilton, Didcot, Oxon
  • A. Enomoto, S. Kuroda, T. Okugi, T. Sanami, Y. Suetsugu, T. Tauchi
    KEK, Ibaraki
  • A. Ferrari
    UU/ISV, Uppsala
  • J. Gronberg
    LLNL, Livermore, California
  • Y. Iwashita
    Kyoto ICR, Uji, Kyoto
  • W. Lohmann
    DESY Zeuthen, Zeuthen
  • L. Ma
    STFC/DL, Daresbury, Warrington, Cheshire
  • T. M. Mattison
    UBC, Vancouver, B. C.
  • T. S. Sanuki
    University of Tokyo, Tokyo
  • V. I. Telnov
    BINP SB RAS, Novosibirsk
  • E. T. Torrence
    University of Oregon, Eugene, Oregon
  • D. Warner
    Colorado University at Boulder, Boulder, Colorado
  • N. K. Watson
    Birmingham University, Birmingham
  • H. Y. Yamamoto
    Tohoku University, Sendai
 
  The beam delivery system for the linear collider focuses beams to nanometer sizes at the interaction point, collimates the beam halo to provide acceptable background in the detector and has a provision for state-of-the art beam instrumentation in order to reach the physics goals. The beam delivery system of the International Linear Collider has undergone several configuration changes recently. This paper describes the design details and status of the baseline configuration considered for the reference design.  
slides icon Slides  
THPMN079 Simulation of ILC Feedback BPM Signals in an Intense Background Environment 2889
 
  • A. F. Hartin, P. Burrows, G. B. Christian, C. I. Clarke, B. Constance, H. D. Khah, C. Perry, C. Swinson, G. R. White
    JAI, Oxford
  • R. Arnold, S. Molloy, S. Smith, M. Woods
    SLAC, Menlo Park, California
  • A. Kalinin
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire
 
  Funding: This work is supported in part by the Commission of the European Communities under the 6th Framework Programme "Structuring the European Research Area", contract number RIDS-011899.

Experiment T-488 at SLAC, End Station A recorded distorted BPM voltage signals and an accurate simulation of these signals was performed. Geant simulations provided the energy and momentum spectrum of the incident spray and secondary emissions, and a method via image charges was used to convert particle momenta and number density into BPM stripline currents. Good agreement was achieved between simulated and measured signals. Further simulation of experiment T-488 with incident beam on axis and impinging on a thin radiator predicted minimal impact due to secondary emission. By extension to worst case conditions expected at the ILC, simulations showed that background hits on BPM striplines would have a negligible impact on the accuracy of beam position measurements and hence the operation of the FONT feedback system

 
FRPMN111 Design and Performance of the LCLS Cavity BPM System 4366
 
  • R. M. Lill, L. H. Morrison, W. E. Norum, N. Sereno, G. J. Waldschmidt, D. R. Walters
    ANL, Argonne, Illinois
  • S. Smith, T. Straumann
    SLAC, Menlo Park, California
 
  Funding: Work supported by U. S. Department of Energy under Contract Nos. DE-AC02-06CH11357 and DE-AC03-76SF00515

In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high resolution X-band cavity BPM. Each BPM has a TM010 monopole reference cavity and a TM110 dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low-noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

 
FRPMS049 Resolution of a High Performance Cavity Beam Position Monitor System 4090
 
  • S. Walston, C. C. Chung, P. Fitsos, J. Gronberg
    LLNL, Livermore, California
  • S. T. Boogert
    Royal Holloway, University of London, Surrey
  • J. C. Frisch, S. Hinton, J. May, D. J. McCormick, S. Smith, T. J. Smith, G. R. White
    SLAC, Menlo Park, California
  • H. Hayano, Y. Honda, N. Terunuma, J. Urakawa
    KEK, Ibaraki
  • Yu. G. Kolomensky, T. Orimoto
    UCB, Berkeley, California
  • P. Loscutoff
    LBNL, Berkeley, California
  • A. Lyapin, S. Malton, D. J. Miller
    UCL, London
  • R. Meller
    Cornell University, Department of Physics, Ithaca, New York
  • M. C. Ross
    Fermilab, Batavia, Illinois
  • M. Slater, M. Thomson, D. R. Ward
    University of Cambridge, Cambridge
  • V. Vogel
    DESY, Hamburg
 
  International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved – ideally using beam-based stability measurements. It has been estimated that RF cavity beam position monitors (BPMs) could provide position measurement resolutions of less than one nanometer and could form the basis of the desired beam-based stability measurement. We have developed a high resolution RF cavity BPM system. A triplet of these BPMs has been installed in the extraction line of the KEK Accelerator Test Facility (ATF) for testing with its ultra-low emittance beam. A metrology system for the three BPMs was recently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame and has demonstrated that the three BPMs behave as a rigid-body to less than 5 nm. To date, we have demonstrated a BPM resolution of less than 20 nm over a dynamic range of ± 20 microns.