Paper |
Title |
Page |
TPPE056 |
Emittance Measurement with Upgraded RF Gun System at SPring-8
|
3348 |
|
- A. Mizuno, H. Dewa, H. Hanaki, T. Taniuchi, H. Tomizawa
JASRI/SPring-8, Hyogo
- M. Uesaka
UTNL, Ibaraki
|
|
|
A single cell S-band RFgun has been developed at the SPring-8 since 1996. The minimum normalized beam emittance, measured with double slits' scanning method in 2002, was 2.3 pi mm mrad at the exit of the gun cavity with charge of 0.1 nC/bunch. In 2004, we installed a following accelerator structure to investigate beam behavior of the whole injector system. In this paper, we report emittance measurement results of upgraded system, using variable quadrupole magnet method. The minimum emittance of 2.0 pi mm mrad with a net charge of 0.14 nC/bunch were able to be measured.
|
|
FPAE063 |
Enhancements of Machine Reliability and Beam Quality in SPring-8 Linac for Top-Up Injection into Two Storage Rings
|
3585 |
|
- H. Hanaki, T. Asaka, H. Dewa, T. Kobayashi, A. Mizuno, S. Suzuki, T. Taniuchi, H. Tomizawa, K. Yanagida
JASRI/SPring-8, Hyogo
|
|
|
SPring-8 has started its top-up operation from May 2004 in order to feed constant photon fluxes to users. The SPring-8 linac has been improved to realize stable and uninterrupted top-up injection into the SPring-8 storage ring and the NewSUBARU storage ring. The beam energy instability of 0.01% rms had been achieved by the following stabilization: RF amplitude and phase stabilization, synchronization of beam timing and linac's 2856 MHz RF and introduction of an energy compensation system (ECS). Feedback controls of steering magnets compensate long-term variation of beam trajectories at ends of beam transport lines. The presentation will include also recent improvements.
|
|