A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Prost, L.R.

Paper Title Page
TPPE035 Efficiency of the Fermilab Electron Cooler’s Collector 2387
 
  • L.R. Prost, A.V. Shemyakin
    Fermilab, Batavia, Illinois
 
  Funding: Operated by Universities Research Association Inc. under Contract No. DE-AC02-76CH03000 with the United States Department of Energy.

The newly installed high-energy Recycler Electron Cooling system (REC) at Fermilab will work at an electron energy of 4.34 MeV and a DC beam current of 0.5 A in an energy recovery scheme. For reliable operation of the system, the relative beam current loss must be maintained to levels < 3.e-5. Experiments have shown that the loss is determined by the performance of the electron beam collector, which must retain secondary electrons generated by the primary beam hitting its walls. As a part of the Electron cooling project, the efficiency of the collector for the REC was optimized, both with dedicated test bench experiments and on two versions of the cooler prototype. We find that to achieve the required relative current loss, an axially-symmetric collector must be immersed in a transverse magnetic field with certain strength and gradient prescriptions. Collector efficiencies in various magnetic field configurations, including without a transverse field on the collector, are presented and discussed

 
FPAT026 The Dynamic Aperture of an Electrostatic Quadrupole Lattice 1946
 
  • C.M. Celata, F.M. Bieniosek, P.A. Seidl
    LBNL, Berkeley, California
  • A. Friedman, D.P. Grote
    LLNL, Livermore, California
  • L.R. Prost
    Fermilab, Batavia, Illinois
 
  Funding: Work supported by the U.S. DOE, under contract numbers DE-AC03-76SF00098 and W-7405-Eng-48.

In heavy-ion-driven inertial fusion accelerator concepts, dynamic aperture is important to the cost of the accelerator, most especially for designs which envision multibeam linacs, where extra clearance for each beam greatly enlarges the transverse scale of the machine. In many designs the low-energy end of such an accelerator uses electrostatic quadrupole focusing. The dynamic aperture of such a lattice has been investigated for intense, space-charge-dominated ion beams using the 2-D transverse slice version of the 3-D particle-in-cell simulation code WARP. The representation of the focusing field used is a 3-D solution of the Laplace equation for the biased focusing elements, as opposed to previous calculations which used a less-accurate multipole approximation. 80% radial filling of the aperture is found to be possible. Results from the simulations, as well as corroborating data from the High Current Experiment at LBNL, will be presented.

 
ROPC006 Commissioning of Fermilab's Electron Cooling System for 8-GeV Antiprotons 540
 
  • S. Nagaitsev, D.R. Broemmelsiek, A.V. Burov, K. Carlson, C. Gattuso, M. Hu, B.J. Kramper, T.K. Kroc, J.R. Leibfritz, L.R. Prost, S.M. Pruss, G.W. Saewert, C.W. Schmidt, A.V. Shemyakin, M. Sutherland, V. Tupikov, A. Warner
    Fermilab, Batavia, Illinois
  • W. Gai
    ANL, Argonne, Illinois
  • G.M. Kazakevich
    BINP SB RAS, Novosibirsk
  • S. Seletsky
    Rochester University, Rochester, New York
 
  A 4.3-MeV electron cooling system has been installed at Fermilab in the Recycler antiproton storage ring and is being currently commissioned. The cooling system is designed to assist accumulation of 8.9-GeV/c antiprotons for the Tevatron collider operations. This paper will report on the progress of the electron beam commissioning effort as well as on detailed plans of demonstrating the cooling of antiprotons.