A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Matias, E.

Paper Title Page
TPPT089 Commissioning and Operations Results of the Industry-Produced CESR-Type SRF Cryomodules 4233
 
  • S.A. Belomestnykh, R.P.K. Kaplan, H. Padamsee, P. Quigley, J.J.R. Reilly, J. Sears, V. Veshcherevich
    Cornell University, Laboratory for Elementary-Particle Physics, Ithaca, New York
  • S. Bauer, M. Pekeler, H. Vogel
    ACCEL, Bergisch Gladbach
  • L.-H. Chang, C.-T. Chen, F.-Z. Hsiao, M.-C. Lin, G.-H. Luo, C. Wang, T.-T. Yang, M.-S. Yeh
    NSRRC, Hsinchu
  • E. Matias, J. Stampe, M.S. de Jong
    CLS, Saskatoon, Saskatchewan
 
  Funding: Work is partially supported by the National Science Foundation.

Upon signing a technology transfer agreement with Cornell University, ACCEL began producing turn-key 500 MHz superconducting cavity systems. Four such cryomodules have been delivered, commissioned and installed in accelerators for operation to date. Two more cryomodules are scheduled for testing in early 2005. One of them will be put in operation at Canadian Light Source (CLS); the other will serve as a spare at Taiwan Light Source (TLS). The commissioning results and operational experience with the cryomodules in CESR, CLS and TLS are presented.

 
ROPA002 CLS: A Fully Open-Source Control System 136
 
  • E. Matias, R. Berg, T. Johnson, R. Tanner, T. Wilson, G. Wright, H.Z. Zhang
    CLS, Saskatoon, Saskatchewan
 
  The Canadian Light Source is one of the first major accelerator facility to adopt a fully open source control system. The control system is based on Experimental Physics and Industrial Control System (EPICS) in use at may other facilities. From the outset CLS utilised RTEMS and Linux as the underlying operating systems for real-time control computers, operator interface computers and servers. When communicating with PLC and other intelligent devices CLS has also adopted a policy of using open communications protocols where possible. Combined these strategies have lead to a system that can easily evolve over the life of the facility without being tied to specific hardware or software suppliers. The operational experience over the past few years has indicates the selected architecture is sufficiently robust and reliable.