A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Lenkszus, F.

Paper Title Page
RPAT084 Design of the APS RF BPM Data Acquisition Upgrade 4156
 
  • R.M. Lill, F. Lenkszus, E. Norum, A. Pietryla
    ANL, Argonne, Illinois
 
  Funding: Work supported by U.S. Department of Energy, Office of Basic Energy Sciences, under Contract No. W-31-109-ENG-38.

The Advanced Photon Source (APS) is a third-generation synchrotron light source in its tenth year of operation. The storage ring employs three different types of beam position monitor (BPM) systems to measure and control beam motion. The monopulse radio frequency (rf) BPM is a broadband (10 MHz) system, which is considered to be the backbone of orbit control. The rf BPM system was designed to measure single-turn and multi-turn beam positions. The rf BPMs are presently suffering from an aging data acquisition system. By replacing only the data acquisition we will revitalize this system for another decade and demonstrate a cost-effective approach to improved beam stability, reliability, and enhanced postmortem capabilities. In this paper we present the design of an eight-channel ADC/digitizer VXI board with a sampling rate of 88 MHz (per channel) and 14-bit resolution coupled with a field-programmable gate array and embedded central processing. We will discuss the upgrade system specifications, design, and prototype test results.