A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Lee, W.W.

Paper Title Page
MPPP003 FALSE BPM READINGS AFFECTING ORBIT FEEDBACK 847
 
  • H.-S. Kang, J. Choi, M.-H. Chun, K.M. Ha, J.Y. Huang, Y.-C. Kim, E.-H. Lee, T.-Y. Lee, W.W. Lee, J.-H. Suh
    PAL, Pohang, Kyungbuk
 
  Funding: Ministry of Science and Technology, Korea.

A slow global orbit feedback (SOFB) is routinely operating in the usual user service operation at PLS. The orbit feedback uses 22 correctors in each plane which have 20-bit capability for the vertical plane and 16-bit capability for the horizontal plane, and the feedback speed is 4 seconds. The orbit stability in RMS was maintained below 1 mm in both planes for one hour and 3 mm for a 12-hour operation. The BPM chamber movement due to the change of synchrotron radiation heat load mainly limits the SOFB performance. The intensity dependence of BPM electronics is well compensated by a look-up table of BPM.

 
MPPT075 Analysis and Design of Backing Beam for Multipole Wiggler (MPW14) at PLS 3940
 
  • H.-G. Lee, C.W. Chung, H.S. Han, Y.G. Jung, D.E. Kim, W.W. Lee, K.-H. Park, H.S. Suh
    PAL, Pohang, Kyungbuk
 
  Pohang Accelerator Laboratory (PAL) had developed and installed a Multipole Wiggler (MPW14) to utilize high energy synchrotron radiation at Pohang Light Source (PLS). The MPW14 is a hybrid type device with period of 14 cm, minimum gap of 14 mm, maximum flux density of 2.02 Tesla and total magnetic structure length of 2056 mm. The support locations and structure of an insertion device are optimized to achieve a minimum deflection due to the magnetic loads. A Finite Element Analysis (FEA) is performed to find out the amount of maximum deflection and optimal support positions on the backing beam, the support and drive structures of the MPW14 under expected magnetic load of 14 tons. To reduce the deflection effect further, two springs are designed and installed to compensate the gap dependent magnetic loads. The optimized deflection is estimated to be about 20.6 ? while the deflection before optimization is 238 ?.  
WPAE016 Development of a Precision Amplifier for the Detector 1514
 
  • K.-H. Park, C.W. Chung, S.-M. Hong, S.-H. Jeong, Y.G. Jung, D.E. Kim, H.-S. Lee, W.W. Lee
    PAL, Pohang, Kyungbuk
  • B.-K. Kang
    POSTECH, Pohang, Kyungbuk
 
  A high gain trans-resistance amplfier has been developed for measuring the intensity of synchrotron radiation at Pohang Light Source(PLS). This amplifier built with discrete elements and operational amplifiers.It had the capability of measuring range from 1pA to 1 uA with good linearity. A microprocessor was also installed to interface the amplifier with the computer, and controlled the other sub-circuits. The various characteristics of amplifier such as linearity, sensitivity,stability, etc. have been investigated, and its experimental results carried out at the beam line are presented in this paper.  
WPAE062 AC Power Supply for Wobbler Magnet of the MC-50 Cyclotron 3576
 
  • Y.-S. Kim, J.-S. Chai
    KIRAMS, Seoul
  • C.W. Chung, H.-G. Lee, W.W. Lee, K.-H. Park
    PAL, Pohang, Kyungbuk
  • B.-K. Kang
    POSTECH, Pohang, Kyungbuk
 
  The MC-50 cyclotron (k=50) produces the ion beam for nuclear physics, chemistry, and applied researches in Korea. It has a small beam diameter with Gaussian beam shape, whereas many users want a beam irradiation on a large target. A wobbler magnet and an AC power supply were designed and constructed to meet the users’ requirement. The power supply has two independently operating channels for the vertical and horizontal coils of the wobbler magnet. The frequency of the AC power supply for both coils is programmable from 1 to 20 Hz in a step of 1 Hz, and the maximum rms output current is 12 A. Various properties of the power supply and experimental results are given in the paper.  
RPAT054 Beam Position Monitor at the PLS BTL 3289
 
  • S.-C. Kim, M.-H. Chun, Y.J. Han, J.Y. Huang, D.T. Kim, W.W. Lee
    PAL, Pohang, Kyungbuk
 
  Funding: Work supported by the Ministry of Science and Technology, Korea.

Electron Linac at the Pohnag Accelerator Laboratory (PAL) has been operated continuously as the full energy injector for storage ring. Linac and storage ring energy has been 2.0 GeV since Dec. 1994, and 2.5 GeV since Oct. 2002. In Aug. 2004, thirteen BPMs are newly installed at BTL(Beam Transport Line) for beam trajectory measurement and feedback. These BPMs consist of 100mm strip-line electrodes in 150mm long chamber, and 500MHz log-ratio signal processing circuits. BPM data acquisition system is developed as EPICS IOC using NI S-series data acquisition board and NI LabView 7.1. BTL BPMs will be used for optic correction and beam energy feedback for PLS beam injection. This paper describes on design, test results, installation and data acquisition system of the PLS BTL BPM.